IFM Flow Meter SD6500-SDR12DGXFRKG/US-100
$229.67
IFM flow meters are increasingly incorporating electronic technologies, such as digital signal processing (DSP) and microprocessors. This enables the flow meters to have self-diagnostic capabilities and better communicate with production control systems. Improved performance better meets the needs of industry users, creating more market application opportunities for flow meters. However, the current global economic situation requires further improvement, and demand for industrial products is weak. Many industry users are slowing down new project investments or suspending equipment upgrades, awaiting signs of global economic recovery. Therefore, in the short term, this will limit the development of flow meters in their main application industries.
Brand
IFM/Germany
Price Range
Negotiable
Product Type
Other
Media Classification
Gas
Origin Category
Imported
Application Fields
Chemical, Petroleum, Mining, Road/Rail/Marine, Comprehensive
IFM Compressed Air Flow Meter
SD6500
SDR12DGXFRKG/US-100
Accurate measurement of flow rate, consumption, pressure, and media temperature
High sensitivity, high repeatability, and high measurement dynamics
For monitoring compressed air in industrial applications
Red/green display for clear identification of acceptable ranges
Rotating display for optimal arrangement
Product Features
Total Inputs and Outputs
Number of Digital Outputs: 2; Number of Analog Outputs: 1
System Interface
Threaded Connection R 1/2 DN15
Pressure Monitoring
Measurement Range [bar]
-1...16
Applications
Applications
For Industrial Applications
Media
Compressed Air
Media Temperature [°C]
-10...60
Minimum Burst Pressure [bar]
64
Minimum Burst Pressure [MPa]
6.4
Compressive Strength [bar]
16
Compressive Strength [MPa]
1.6
Maximum Allowable Working Pressure (for applications conforming to CRN standards) [bar]
9.7
Electrical Data
Operating Voltage [V]
18...30 DC; (according to SELV/PELV)
Current Dissipation [mA]
< 80
Protection Class
III
Reverse Phase Protection
Yes
Start-up Delay Time [s]
1
Total Inputs/Outputs
Total Number of Inputs and Outputs
Number of Digital Outputs: 2; Number of Analog Outputs: 1
Inputs
Inputs
Counter Reset
Outputs
Output Signals
Switch Signal; Analog Signal; Pulse Signal; IO-Link; (Configurable)
Electrical Design
PNP/NPN
Number of Digital Outputs
2
Output Function
Normally Open/Normally Closed; (Settable parameter) Maximum DC voltage drop of digital output [V]
2.5
Continuous current load of digital output DC [mA]
150; (per output)
Number of analog outputs
1
Analog current output [mA]
4...20; (adjustable range)
Maximum load [Ω]
500
Pulse output
Flow meter
Short circuit protection
Yes
Short circuit protection type
Pulse
Overload protection
Yes
Measurement/setting range
Measurement range
4...1250 l/min
0.3...99.8 m/s
0.25...75 m³/h
Display range
0...1500 l/min
0...119.8 m/s
0...90 m³/h
Resolution
1 l/min
0.1 m/s
0.05 m³/h
Switching point, SP
11...1250 l/min
0.9...99.8 m/s
0.65...74.97 m³/h
Recovery Point, rP
5...1243 l/min
0.4...99.3 m/s
0.28...74.6 m³/h
Measurement Start Point, ASP
0...1000 l/min
0...79.8 m/s
0...60 m³/h
Measurement End Point, AEP
250...1250 l/min
20...99.8 m/s
15...75 m³/h
Low Flow Cut-off, LFC
1...13 l/min
0.1...1.1 m/s
0.09...0.8 m³/h
Step Size
1 l/min
0.1 m/s
0.01 m³/h
Monitoring Pressure
Measurement Range [bar]
-1...16
Display Range [bar]
-1...20
Resolution [bar]
0.05
Switch Point, SP [bar]
-0.92...16
Recovery Point, rP [bar]
-1...15.92
Measurement Start Point [bar]
-1...12.8
Measurement End Point [bar]
2.2...16
Set Step Size [bar]
0.01
Flow Monitoring
Measurement Range
0...100000000 m³
0...353146667.2 scf
Display Range
0...100000000 m³
0...353146667.2 scf
Switch Point, SP
0.001...10000000 m³
0.05...353146667.2 scf
Pulse Value
0.001...10000000 m³
0.05...353146667.2 scf
Set Step Size
0.0001 m³
0.005 scf
Pulse Length [s]
0.002...2
Temperature Monitoring
Measurement Range
-10...60 °C
14...140 °F
Display Range
-24...74 °C
-11.2...165.2 °F
Resolution
0.2 °C
0.5 °F
Switch Point, SP
-9.7...60 °C
14.6...140 °F
Reset Point, rP
-10...59.7 °C
14...139.4 °F
Measurement Start Point
-10...46 °C
14...114.8 °F
Measurement End Point
4...60 °C
39.2...140 °F
Set Step Size
0.1 °C
0.1 °F
Accuracy/Bias
Temperature Coefficient [1/K]
± 0.07 % MW
Accuracy (within the measuring range)
class 141: ± (2 % MW + 0.5 % MEW); class 344: ± (6 % MW + 0.6 % MEW); Air quality conforms to ISO 8573-1:2010; at medium temperature 23 °C
Repeatability
± (0.4 % MW + 0.1 % MEW)
Monitoring Pressure
Repeatability [Percentage of Final Value]
± 0.2
Characteristic Curve Deviation [Percentage of Final Value]
< ± 0.5; (BFSL = Best Fit Straight Line)
Maximum Temperature Coefficient of Measuring Range Value [% MEW / 10 K]
± 0.3 Maximum temperature coefficient at zero point [% MEW / 10 K]
± 0.1
Temperature monitoring
Accuracy [K]
± 0.5; (Medium flow rate within the limits of the flow measurement range)
Response time
Response time [s]
0.1; (dAP = 0)
Damping process value dAP [s]
0...5
Pressure monitoring
Response time [s]
0.05
Temperature monitoring
Response time T05 / T09 [s]
T09 = 0.5
Software/Programming
Parameter settings
Hysteresis/Window; Normally open/Normally closed; Current output/Pulse output; Rotatable and switchable display; Display units; Accumulator
Interface
Communication interface
IO-Link
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9 CDV
Form type
Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000)
SIO Mode
Yes
Required Main Port Type
A
Analog Process Data
8
Two-Digit Output Process Data
2
Minimum Processing Cycle [ms]
7.2
Supported DeviceID
Operating Mode
DeviceID
Default
862
Operating Conditions
Ambient Temperature [°C]
0...60
Storage Temperature [°C]
-20...85
Maximum Allowable Relative Humidity [%]
90
Enclosure Protection Rating
IP 65; IP 67
Certifications/Tests
EMC Electromagnetic Compatibility
DIN EN 60947-5-9
CPA Certification
Model
001TG
Accuracy Class
-
Maximum Permissible Error
± 2.5 % FS
Q (min)
0.25 m³/h
Q (t)
-
Q (max) 75 m³/h
Seismic Resistance
DIN EN 68000-2-6
5 g (10...2000 Hz)
MTTF [Year]
183
UL Certification
UL Certification Number
I012
Number of Documents UL
E174189
Pressure Equipment Directive
Good Engineering Practice; Suitable for Stable Gas and Liquid Group 2
Mechanical Technical Data
Weight [g]
728.5
Raw Materials
PBT+PC-GF30; PPS-GF40; Stainless Steel (1.4301/304); Stainless Steel (1.4305/303); Steel (1.5523) Zinc-plated; Brass (2.0401); FKM
Materials (Wet Components)
Stainless Steel (1.4301/304); Stainless Steel (1.4305/303); FKM; Ceramic Glass Passivated; PPS-GF40; Al2O3 (Ceramic); Acrylic
System Interface
Threaded Connection R 1/2 DN15
Display/Operator
Display
Color Display 1.44", 128 x 128 pixels
2 x LEDs, Yellow
Notes
Notes
MW = Measured Value
MEW = Final value of the measuring range
According to German Industrial Standard DIN ISO 2533, the measurement, display, and setting range is for standard volumetric flow rate.
For installation and usage instructions, please refer to the user guide.
Packaging Unit
1 Piece
Electrical Connection
Interface
Connector: 1 x M12; Decoder: A
Our company mainly deals in European and American brands and can purchase brands from any European country. For example, our advantageous German brands include: BURKERT, DEMAG, HAWE, AVENTICS, HYDAC, PILZ, FESTO, and IFM. Door sensors: E+H (Germany), HEIDENHAIN (Germany), P+F (Germany), SICK (Germany), TURCK (Germany), HIRSCHMANN (Germany) industrial switches; Hengstler (Germany), MURR (Germany), SCHMERSAL (Germany), SAMSON (Germany), EPRO (Germany, Emerson's subsidiary); MOOG (USA), ASCO (USA) solenoid valves, MAC (USA) solenoid valves, NUMATICS (USA), PARKER (USA), VICKERS (USA), ROSS (USA); Norgren (UK); OMAL (Italy), ATOS (Italy), CAMOZZI (Italy), UNIVER (Italy), Camozzi (Italy)