German IFM pressure sensor PQ3809 in stock
$399.06
Reliable monitoring of system pressure in pneumatic and compressed air systems; overpressure and vacuum resistant; clearly visible tilting LED display with red/green indicator for clear identification of acceptable ranges; programmable switch output and analog output.
Brand
IFM/Germany
Application Areas
Oil, Mining, Road/Rail/Marine, Electrical, Integrated
IFM Pressure Sensors (Germany)
IFM pressure sensors are used in almost all manufacturing processes and plant engineering for cooling and lubricating equipment and devices with liquids or gases, for ventilation and exhaust in units and buildings, and for processing products. The absence of flow in these media leads to significant losses and downtime, making their monitoring crucial. Therefore, electronic flow sensors are essential in modern equipment. They have no mechanical parts, operate without wear, and ensure accurate monitoring over long periods, even in complex media.
IFM Pressure Sensor Working Principle
IFM's electronic flow sensors employ various measurement principles. They can meet all requirements, from simple monitoring functions to precise flow measurement. A convenient and flexible operating menu ensures users can quickly and easily set up sensors when using different flow sensors. Some flow sensors also have temperature monitoring capabilities, eliminating the need for additional temperature measuring elements. This ensures optimal process control and saves energy. Analog, digital, and pulse outputs offer diverse processing options for the measured data. Flexible key settings allow the sensor to be used in a variety of conditions. The sensor can be mounted via an adapter.
Pressure Sensor for Pneumatic Systems
PQ3809
PQ-1-1-KHR18-KFPKG/AS/
Reliable monitoring of system pressure in pneumatic and compressed air systems
Overpressure and vacuum resistant
Clearly visible tilted LED display
Red/green display for clear identification of acceptable ranges
With programmable switch outputs and analog outputs
Product Features
Total Inputs and Outputs
Number of Digital Outputs: 1; Number of Analog Outputs: 1
Measuring Range
-1...1 bar
-1000...1000 mbar
-14.6...14.6 psi
-29.4...29.4 inHg
-100...100 kPa
System Interface
Threaded Connection G 1/8 Internal Thread Internal Thread: M5
Applications
Special Performance
Gold-plated Contacts
Applications
For Industrial Applications
Conditionally Applicable
Other Media as Required
Media Temperature [°C]
0...60
Minimum Burst Pressure 30 bar
435 psi
886 inHg
3000 kPa
Minimum burst pressure note
Maximum overpressure for second pressure connection: 12 bar / 1200 kPa / 174 PSI / 354.4 inHg / 1.2 MPa
Pressure resistance
20 bar
290 psi
591 inHg
2000 kPa
Vacuum resistance [mbar]
-1000
Pressure
Relative pressure; Differential pressure; Vacuum
Electrical data
Operating voltage [V]
18...32 DC; (according to SELV/PELV)
Current loss [mA]
< 50
Minimum insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse phase protection
Yes
Overvoltage protection
Yes; (< 40 V)
Start-up delay time [s] 0.5
Watchdog Integrated Circuit
Yes
Total Inputs/Outputs
Total Number of Inputs and Outputs
Number of Digital Outputs: 1; Number of Analog Outputs: 1
Outputs
Number of Outputs
2
Output Signals
Switching Signal; Analog Signal; IO-Link; (Configurable)
Electrical Design
PNP
Number of Digital Outputs
1
Output Function
Normally Open/Normally Closed; (Settable Parameter)
Maximum DC Voltage Drop of Switch Output [V]
2
Continuous Current Load of Switch Output [mA]
100
Switching Frequency DC [Hz]
< 100
Number of Analog Outputs
1
Analog Current Output [mA]
4...20
Maximum Load [Ω]
500
Short Circuit Protection
Yes
Short Circuit Protection Type
Pulse
Measurement/Setting Range
Measurement Range
-1...1 bar
-1000...1000 mbar
-14.6...14.6 psi
-29.4...29.4 inHg
-100...100 kPa
Switch Point, SP
-0.98...1 bar
-14.2...14.6 psi
-28.8...29.4 inHg
-98...100 kPa
Recovery Point, rP
-0.99...0.99 bar
-14.4...14.4 psi
-29.1...29.1 inHg
-99...99 kPa
Setting Step
0.01 bar
0.2 psi
0.3 inHg
1 kPa
Accuracy/Bias
Switch Point Accuracy [% of Measurement Range Value]
< ± 0.5
Repeatability Accuracy [% of Measurement Range Value]
< ± 0.1; (Temperature Fluctuation < 10 K)
Characteristic Curve Bias [% of Measurement Range Value]
< ± 0.25 (BFSL) / < ± 0.5 (LS); (BFSL = Best Fit Straight Line; LS = Limit Point Setting)
Hysteresis [% of Measurement Range Value]
< ± 0.25
Long-Term Stability [% of Measurement Range Value]
< ± 0.05; (every 6 months)
Temperature Coefficient Zero Point [Percentage of Measurement Range Value / 10 K]
0.2; (0...60 °C)
Temperature Coefficient Range [Percentage of Measurement Range Value / 10 K]
0.2; (0...60 °C)
Response Time
Response Time [ms]
< 6
Programmable Delay Time dS, dr [s]
0; 0.002...5
Step Function Response Time Analog Output [ms]
6
Software/Programming
Parameter Settings
Hysteresis/Window; Normally Open/Normally Closed; Analog Output; IO-Link; Output Polarity; ON Delay, Off Delay; Damping; Display Unit
Interface
Communication Interface
IO-Link
Transmission Type
COM2 (38.4 kBaud)
IO-Link Revision
1.1
SDCI Standard
IEC 61131-9 FDIS
Form Factor
Smart Sensor: Process Data Variable; Device Identification
SIO Mode
Yes
Required Device Port Type
A
Analog Process Data
1
Two-bit Output Process Data
2
Minimum Processing Cycle [ms]
2.3
Supported DeviceID
Operating Mode
DeviceID
Default
366
Operating Conditions
Ambient Temperature [°C]
0...70
Storage Temperature [°C]
-25...85
Enclosure Protection Rating
IP 65
Certifications/Testing
EMC Electromagnetic Compatibility
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock Resistance
DIN EN 60068-2-27
50 g (11 ms)
Shockproof
DIN EN 60068-2-6
20 g (10...2000 Hz)
MTTF [Year]
437
Pressure Equipment Directive
Good Engineering Practice; Applicable to Group 2 fluids; Group 1 fluids as required
Mechanical Technical Data
Weight [g]
87
Raw Materials
PBT; FKM; Polyester
Materials (Wetted Parts)
Brass; FKM; Silicon (Coating); PBT
Switch Operation Life
50 Million KWh
System Interface
Threaded Connection G 1/8 Internal Thread Internal Thread: M5
Indicator/Operator
Display
Display Units
4 x LEDs, Green
Switch Status
1 x LED, Yellow
Function Display
Alphanumeric Display, 4 Digits
Measured Value
Alphanumeric Display, 4 Digits
Display Units
bar; kPa; psi; inHg
Notes
The company mainly deals in European and American brands and can purchase brands from any European country. For example, our advantageous German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengstler, Murr, Schmersal, Samson, EPRO (Emerson Group)
American brands: MOOG, ASCO, MAC, NUMATICS, PARKER, Vickers, Helón (Norgren)
Italian brands: OMAL, ATOS, CAMOZZI, UNIVER, Camozzi