If the coil of an Italian ATOS solenoid valve burns out, disconnect the solenoid valve wiring and use a multimeter to measure it. If an open circuit is found, the solenoid valve coil is burnt out. Causes include moisture in the coil causing poor insulation and magnetic leakage, resulting in excessive current and burnout. Therefore, prevent rainwater from entering the solenoid valve. Additionally, an overly stiff spring, excessive reaction force, or too few coil turns resulting in insufficient suction can also cause the coil to burn out. In an emergency, the manual button on the coil can be switched from the normal "0" position to the "1" position to open the valve.


Brand

ATOS/Italian Atos

Flow Direction

Other

3C Valve Category

Industry

Application Areas

Chemical, Petroleum, Mining, Road/Rail/Marine, Comprehensive

ATOS Solenoid Valve Performance Requirements and Service Life

ATOS Solenoid Directional Control Valve, ATOS Pressure Reducing Valve, ATOS Safety Valve, ATOS Control Valve

ATOS Solenoid Valve Performance Requirements

1. ATOS Solenoid Valve Reversing Performance

Under specified operating conditions, can the solenoid valve reliably reverse direction after being energized, and reliably reset after being de-energized?

2. ATOS Solenoid Valve Pressure Loss

The pressure loss of a solenoid directional control valve consists of flow loss and throttling loss generated when the fluid flows through the valve orifice.

3. ATOS Solenoid Valve Internal Leakage

The internal leakage of a solenoid directional control valve refers to the leakage from the high-pressure chamber to the low-pressure chamber under specified operating conditions and in various operating positions. 4. ATOS Solenoid Valve Switching and Reset Time

The time required from the energization of the solenoid to the termination of the valve spool switching. Reset time refers to the time required from the de-energization of the solenoid to the return of the valve spool to its initial position.

5. ATOS Solenoid Valve Switching Frequency

The maximum number of switching operations allowed per unit time.

6. ATOS Solenoid Valve Service Life

The service life of an ATOS solenoid valve is defined as the number of switching operations it can withstand until major components fail, preventing normal switching and reset actions, or until its main performance indicators significantly deteriorate beyond the specified number of switching operations.

An ATOS solenoid valve consists of an electromagnetic coil and a magnetic core, and is a valve body containing one or more orifices. When the coil is energized or de-energized, the rotation of the magnetic core causes flow through the valve body or is cut off, thereby changing the direction of the fluid.

The electromagnetic components of an ATOS solenoid valve consist of a stationary iron core, a moving iron core, and a coil; the valve body consists of a spool, a spool sleeve, and a spring base. The electromagnetic coil is directly mounted on the valve body, which is enclosed in a sealing tube, forming a simple and compact assembly. Commonly used solenoid valves in production include 2-position 2-way and 2-position 3-way valves. The term "two positions" refers to energized and de-energized states for a solenoid valve, and open and closed states for the valve it controls.

ATOS solenoid valves are electromagnetically controlled industrial devices, fundamental components of automation systems used to control fluids. They are actuators, not limited to hydraulic or pneumatic systems. They are used in industrial control systems to adjust the direction, flow rate, speed, and other parameters of the medium.

ATOS solenoid valves can be used with different circuits to achieve the desired control, ensuring both precision and flexibility. There are many types of solenoid valves, each playing a different role in the control system. Common types include check valves, safety valves, directional control valves, and speed control valves.

DHU-6751/2P-X 24DC

DKI-1610/A-X 24DC 24

DKI-1610-X 24DC

DKI-1611-X 24DC

DKI-1612/A-X 230/50/60AC 24

DKI-1612-X 24DC 24

DKI-1613/A-X 24DC 24

DKI-1613-X 24DC 24

DKI-1618-X 24DC 24

DKI-1630/2/A-X 24DC 24

DKI-1630/2-X 24DC

DKI-1631/2/A-X 24DC 24

DKI-1631/2/WP 24DC DKI-1631/2/WP-X 230/50/60AC 24

DKI-1631/2-X 230/50/60AC 24

DKI-1631/2-X 24DC

DKI-1632/2/AFI/NC-X 24DC 24

DKI-1632/2/A-X 24DC 24

DKI-1671-X 24DC 24

DKI-1710-X 24DC

DKI-1711/WP-X 24DC 24

DKI-17116-X 24DC

DKI-17119-X 110/50/60AC 24

DKI-17119-X 230/50/60AC

DKI-1711-X 110/50/60AC 24

DKI-1711-X 230/50/60AC

DKI-1711-X 24DC

DKI-1713/1-X 24DC 24

DKI-1713/WP-X 230AC

DKI-1713-X 230/50/60AC

DKI-1713-X 24DC

DKI-1714-X 110/50/60AC 24

DKI-1714-X 24DC

DKI-1715-X 230/50/60AC 24

DKI-1717-X 24DC 24

DKI-1718-X 24DC 24

DKI-1750/2-X 24DC DKI-1751/2/FI/NC-X 24DC 24

DKI-1751/2/FI/NO-X 24DC 24

DKI-1751/2/WP-X 230/50/60AC 24

DKI-1751/2-X 24DC

SDHI-0631/2

DKE-1631/2 The company mainly deals with European and American brands and can source brands from any European country. For example, our key German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengstler, Murr, Schmersal, Samson, EPRO (Emerson Group)

American brands: MOOG, ASCO, MAC, NUMATICS, PARKER, VICKERS, ROSS

British brands: Norgren

Italian brands: OMAL, ATOS, CAMOZZI, UNIVER, Camozzi

Fast Shipping
Fast shipping for order above $100 by UPS or FedEx
Money Back Guarantee
Within 30 days for an exchange
Flexible Payment
Pay with credit card, PayPal or COD
24/7 Support
Get support at any time