Italian ATOS solenoid valve DHA-0713/NPT/BT in stock
$184.49
Italian ATOS solenoid valve DHA-0713/NPT/BT in stock
Brand
ATOS/Italian Atos
Flow Direction
Other
3C Valve Category
Industry
Application Areas
Chemical, Petroleum, Mining, Road/Rail/Marine, Comprehensive
Thank you for your interest in our products. If you would like to learn more, such as the price and specifications of ATOS products, please feel free to contact us. We sincerely invite you to experience our satisfactory service!
ATOS solenoid valves consist of an electromagnetic coil and a magnetic core, and are valve bodies containing one or more orifices. When the coil is energized or de-energized, the rotation of the magnetic core causes the flow to pass through the valve body or be cut off, thereby changing the flow direction. The electromagnetic components of the solenoid valve consist of a stationary iron core, a moving iron core, and a coil; the valve body consists of a spool, a spool sleeve, and a spring base. The electromagnetic coil is directly mounted on the valve body, which is enclosed in a sealing tube.
ATOS solenoid valves form a simple and compact combination. Commonly used solenoid valves in our production include 2-position 2-way and 2-position 3-way valves. The term "two positions" refers to energized and de-energized states for a solenoid valve, and open and closed states for the valve it controls. When current flows through the coil, it generates an excitation effect, attracting the moving iron core to the fixed iron core. The moving iron core then drives the spool valve core and compresses the spring, changing the position of the spool valve core and thus changing the direction of the fluid. When the coil is de-energized, the spring force pushes the spool valve core back, causing the fluid to flow in its original direction.
Common ATOS solenoid valve malfunctions include the solenoid valve not operating. Troubleshooting should be done in the following ways:
(1) The solenoid N terminal is loose or the wire is detached. The solenoid valve will not be energized. Tighten the wire. (2) If the solenoid valve coil is burnt out, disconnect the solenoid valve wiring and measure with a multimeter. If it is open-circuited, the solenoid valve coil is burnt out. This can be caused by the coil being subjected to heat, leading to poor insulation and magnetic leakage, resulting in excessive current and burnout. Therefore, prevent rainwater from entering the solenoid valve. Additionally, an overly stiff spring, excessive reaction force, or too few coil turns and insufficient suction can also cause the coil to burn out.
(3) If the ATOS solenoid valve is stuck, the clearance between the valve sleeve and the valve core is very small. When mechanical impurities are introduced or the valve body is rusted, it can easily become stuck. The fundamental solution is to disassemble the solenoid valve, remove the N core and valve core sleeve, and clean them with CCI4 to ensure the valve core moves freely within the valve sleeve. During disassembly, pay attention to the assembly sequence of each component and the position of the external wiring to ensure correct reassembly and wiring. (5) If it is a pilot-operated solenoid valve, check if the differential pressure in the pipeline is too small. If the differential pressure is too small, the solenoid valve will not work properly. In this case, a direct-acting solenoid valve should be selected. If the differential pressure is too large, far exceeding the design value of the solenoid valve N, it will also not work properly. In this case, a high-performance solenoid valve should be used.
(6) If dirt in the pipeline blocks the small hole of the pilot valve, the pilot valve cannot open properly, and the main valve cannot open in time. The valve body can be disassembled, the dirt cleaned, and reassembled to work properly.
(7) In addition, solenoid valves are generally installed horizontally. If they are side-mounted, it may cause the valve to not close tightly, i.e., internal leakage. Side-mounting should be avoided as much as possible.
ATOS Solenoid Valve Stock List:
DHI-0715-X 24DC
DHI-0716-X 24DC
DHI-0717-X 24DC
DHI-0718-X 230/50/60AC
DHI-0718-X 24DC DHI-0750/2-X 24DC
DHI-0751/2/FI/NC-X 24DC 23
DHI-0751/2/FI/NO-X 24DC 23
DHI-0751/2/WP-X 230/50/60AC
DHI-0751/2/WP-X 230/50/60AC 23/PE
DHI-0751/2/WP-X 24DC
DHI-0751/2-X 110/50/60AC 23
DHI-0751/2-X 230/50/60AC
DHI-0751/2-X 24DC
DHO-0630/2/A-X 24DC 20
DHO-0631/2/A-X 24DC 20 DHO-0631/2/L1-X 24DC 20
DHO-0631/2-X 24DC
DHO-0639/O-X 24DC 20
DHO-0710-X 24DC 20
DHO-0711-X 24DC
DHO-0713-X 24DC 20
DHO-07191-X 24DC
DHO-0750/2-X 24DC 20
DHRZO-P5-012/25 20
DHU-0610/A-X 24DC 20
DHU-0610/FI/NC-X 24DC 20
DHU-0610-X 24DC 20
DHU-0610-X 48DC 20
DHU-0611-X 24DC DHU-0614/A-X 24DC 20
DHU-0614-X 24DC 20
DHU-06191-X 24DC 20
DHU-06194-X 24DC 20
DHU-0630/2/A-X 24DC
DHU-0630/2-X 24DC
DHU-0631/2/A-X 24DC
DHU-0631/2/FC-X 24DC 20
DHU-0631/2-X 24DC
DHU-0632/2/A-X 24DC 20
DHU-0632/2-X 24DC 20
DHU-0639/C-X 24DC 20
DHU-0671-X 24DC
DHU-0710/L1-X 24DC 20
DHU-0710-X 24DC
DHU-0711/WP-X 24DC 20
DHU-07119-X 24DC 20
DHU-0711-X 24DC
DHU-0713/1-X 24DC
DHU-0713/WP-X 24DC 20
DHU-0713P-X 24DC 20
DHU-0713-X 24DC
DHU-07149-X 24DC 20
DHU-0714-X 24DC
DHU-0718-X 24DC
DHU-0750/2/FI/NC-X 24DC 20
DHU-0750/2-X 24DC
DHU-0751/2-00 20 /WG DHU-0751/2P-X 24DC 20
DHU-0751/2-X 24DC
DHU-6751/2P-X 24DC
Common Faults of ATOS Solenoid Valves:
ATOS solenoid valves consist of an electromagnetic coil and a magnetic core, and are valve bodies containing one or more orifices. When the coil is energized or de-energized, the rotation of the magnetic core causes fluid to flow through the valve body or be cut off, thereby changing the direction of fluid flow. The electromagnetic components of a solenoid valve consist of a fixed iron core, a moving iron core, and a coil; the valve body consists of a spool, a spool sleeve, and a spring base. The electromagnetic coil is directly mounted on the valve body, which is enclosed in a sealing tube, forming a simple and compact assembly. Commonly used solenoid valves in production include 2-position 3-way, 2-position 4-way, and 2-position 5-way valves. Here, let's first explain the meaning of "2-position": for a solenoid valve, it means energized and de-energized; for the valve it controls, it means open and closed.
A malfunction of the ATOS solenoid valve will directly affect the operation of the switching valve and the regulating valve. A common fault is that the solenoid valve does not operate. The following troubleshooting steps should be taken:
1. Loose or detached wiring of the ATOS solenoid valve. The solenoid valve will not be energized. Tighten the wiring.
2. Burned-out ATOS solenoid valve coil. Disconnect the solenoid valve wiring and use a multimeter to measure. If an open circuit is found, the solenoid valve coil is burnt out. This can be caused by moisture in the coil, leading to poor insulation and magnetic leakage, resulting in excessive current and burnout. Therefore, prevent rainwater from entering the solenoid valve. Additionally, an overly stiff spring, excessive reaction force, or insufficient coil turns can also cause the coil to burn out due to insufficient suction. In an emergency, the manual button on the coil can be switched from the normal "0" position to the "1" position to open the valve. 3. ATOS Solenoid Valve Jammed: The clearance between the solenoid valve's spool sleeve and valve core is very small (less than 0.008mm), and it is usually assembled as a single piece. When mechanical impurities are introduced or there is insufficient lubrication, it can easily become jammed. A temporary fix is to insert a steel wire through the small hole at the head to make it spring back. The fundamental solution is to disassemble the solenoid valve, remove the valve core and valve core sleeve, and clean them with CCI4 to ensure the valve core moves freely within the valve sleeve. During disassembly, pay attention to the assembly sequence of each component and the location of external wiring to ensure correct reassembly and wiring. Also check if the lubricator spray hole is blocked and if there is sufficient lubrication.
4. Air Leakage: Air leakage will cause insufficient air pressure, making it difficult for the forced valve to open and close. This is caused by damaged gaskets or worn spool sleeves, resulting in air leakage between several cavities. When troubleshooting solenoid valve malfunctions in switching systems, choose an appropriate time to address the issue when the solenoid valve is de-energized. If the problem cannot be resolved within one switching interval, pause the switching system and address the issue at a later time. The company primarily deals in European and American brands, and can source brands from any European country. For example, its key German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, HIRSCHMANN industrial switches, Henschler, MURR, SCHMERSAL, SAMSON, and EPRO (a subsidiary of Emerson).
American brands include MOOG, ASCO solenoid valves, MAC solenoid valves, NUMATICS, PARKER pneumatics and hydraulics, VICKERS, and ROSS.
British brands include Norgren. Italian brands OMAL, ATOS, CAMOZZI, UNIVER, and Camozzi.

