HYDAC pressure switch (Germany) technical parameters: Measuring range: -100Kpa~200MPa; Power supply voltage: 12~35V DC (24V DC calibration voltage)/AC 220VAC; Output relay capacity: 380V 3A, 220V 5A, 24V DC 5A, etc.; Accuracy: Better than 0.0.5%FS, 1%FS, etc.; Setting range: Full range; Settable sampling rate: 10 times/second (customizable according to customer requirements); Interface thread: M20*1.5, G.


Brand

HYDAC/Germany

Application Areas

Chemical, Petroleum, Energy, Electrical, General

HYDAC Pressure Switches, HYDAC Filters, HYDAC Filter Elements, HYDAC Coolers

The HYDAC pressure switch is a simple pressure control device. When the measured pressure reaches the rated value, the pressure switch can issue an alarm or control signal. The working principle of the pressure switch is: when the measured pressure exceeds the rated value, the free end of the elastic element is displaced, directly or after comparison, pushing the switching element, changing the on/off state of the switching element, thus achieving the purpose of controlling the measured pressure.

HYDAC Pressure Switch Main Features

HYDAC pressure switches are mainly classified into normally open and normally closed types. The main features are:

1. Utilizing British standard pipe thread quick couplings or copper pipe welded installation structure, installation is flexible and convenient, requiring no special installation fixation.

2. Plug-in or wire connection methods are available for user selection.

3. Sealed stainless steel sensor ensures safety and reliability.

4. Can be manufactured according to any pressure value selected by the user within the pressure range.

A pressure switch is a device combined with an electrical switch. When a preset fluid pressure is reached, the switch contacts activate. It is mainly used in power plants, petrochemical plants, metallurgical industries, and other industrial equipment to output alarm or control signals. It plays an important role in the industrial field, preventing damage to important equipment in production processes and avoiding major production accidents.

2. Main Sensing Elements of Pressure Switches

2.1 Bellows

Features: Better durability and vibration resistance than Bourdon tubes; wide adjustable range of contact differential; main materials include stainless steel and phosphor bronze; relatively high price; but smaller measurable pressure range, maximum 40MPa (CB33).

2.2 Diaphragm

Features: Excellent corrosion resistance; main materials include NBR and fluororubber; such as the CS and CL series, which use this type of sensitive element. Pressure switches are included in the Quick & Easy Automation Selection Guide.

HYDAC Pressure Switch Operation Method

1. Method for Setting Control Pressure

(1) Briefly press the (ON/OFF) run button to turn off the run indicator light; the pressure control system will then shut down. (2) Setting the Upper/Lower Limit

Press the SET button once to enter the lower limit setting state (the corresponding lower limit indicator light will illuminate). Set the value using (▲) and (▼). After setting the lower limit, press the SET button again to enter the upper limit setting state, using the same method.

(3) After setting, press the SET button to automatically save the set value to the computer chip (if no button operation is performed within 5 seconds after parameter modification, the current parameter setting will be automatically saved).

(4) Press the (ON/OFF) run button again (the corresponding run indicator light will illuminate), and the motor will start working.

2. Unit Switching Method: Press the (ON/OFF) run button briefly to turn off the run indicator light. Press the increase button (▲) briefly to switch the unit between MPa, Kg/cm, and PSI. Turn on the run indicator light after setting.

3. Zero Point Reset Function: Press the (ON/OFF) run button briefly to turn off the run indicator light. Press and hold the decrease button (▼) for 5 seconds to reset the current pressure value to zero and correct the zero point error. Turn on the run indicator light after setting. (Pressure must not be applied to the pressure switch when using this function.)

HYDAC Technology GmbH specializes in the production of components and devices for fluid filtration, hydraulic control, and electronic measurement technologies. It is a world-renowned manufacturer of hydraulic components, including filters, accumulators, hydraulic valves, electronic products, pipe clamps, electromagnets, and hydraulic system assemblies. HYDAC products have a wide range of applications, covering almost all industries, particularly in metallurgy, automotive, power equipment, chemical, construction machinery, papermaking, shipbuilding, and machine tool manufacturing.

HYDAC Pressure Sensor Performance Parameters:

HYDAC offers a wide variety of pressure sensors with varying performance characteristics. Choosing the right sensor for your needs is crucial for cost-effectiveness and efficiency.

1. Rated Pressure Range

The rated pressure range is the pressure range that meets the standard specifications. In other words, it's the pressure range between the maximum pressure and the specified operating pressure that the sensor outputs within the specified operating characteristics. In practical applications, the pressure measured by the sensor falls within this range. Currently, the highest measurement pressure of these sensors can reach 300 MPa or higher.

2. Maximum Pressure Range

The maximum pressure range refers to the maximum pressure the sensor can withstand for an extended period without altering its output characteristics. Especially for semiconductor pressure sensors, the rated pressure range is typically significantly reduced to improve linearity and temperature characteristics. Therefore, continuous use above the rated pressure will not cause damage. Generally, the maximum pressure is 2-3 times the highest rated pressure.

3. Damage Pressure

Damage pressure refers to the maximum pressure that can be machined onto the sensor without damaging the sensor element or housing.

4. Linearity

Linearity refers to the maximum deviation from the linear relationship between the sensor output and the pressure within the operating pressure range.

5. Pressure Hysteresis

This is the difference in sensor output as the sensor approaches a certain pressure from the minimum and maximum operating pressures at room temperature and within the operating pressure range.

6. Temperature Range

The temperature range of a pressure sensor is divided into the compensated temperature range and the operating temperature range. The compensated temperature range is the temperature range within which accuracy falls within the rated range after temperature compensation is applied. The operating temperature range is the temperature range within which the pressure sensor ensures normal operation.

HYDAC pressure sensors from Germany are among the most commonly used sensors in industrial practice. They are widely used in various industrial automation environments, including water conservancy and hydropower, railway transportation, intelligent buildings, production automation, aerospace, military, petrochemical, oil wells, power, shipbuilding, machine tools, pipelines, and many other industries. Below is a brief introduction to the principles and applications of some commonly used sensors. Also available are medical pressure sensors:

HDA 4745-A-0600-S00 909098 hydac 3402

HDA 4745-B-160-000 909103 hydac 3116

HDA 4745-A-0250-S00 909291 hydac 3402

HDA 4745-A-600-031(500bar) 909385 hydac 3361

HDA 4745-A-0400-S00 909468 hydac 3402

HDA 4745-A-0006-S00 909497 hydac 3402

HDA 4745-A-0060-S00 909551 hydac 3402

HDA 4745-A-600-031(450bar) 909682 hydac 3361

HDA 4745-A-400-031(315bar) 909729 hydac 3361

HDA 4745-A-0250-AN1-000 909761 hydac 3964

HDA 4745-A-0016-AN1-000 909763 hydac 3964

HDA 4745-A-0006-AH1-000 909815 hydac 3964

HDA 4745-A-0016-AH1-000 909816 hydac 3964

HDA 4745-A-0100-AH1-000 909817 hydac 3964

HDA 4745-A-0250-AH1-000 909818 hydac 3964

HDA 4745-A-0400-AH1-000 909819 hydac 3964

HDA 4745-A-0600-AH1-000 909820 hydac 3964

HDA 4745-A-0060-AH1-000 920255 hydac 3964

HDA 4745-A-0250-AN7-000 920330 hydac 3964

HDA 4745-A-400-031(280bar) 920447 hydac 3361

HDA 4745-A-0400-AN1-000 920729 hydac 3964

HDA 4745-A-0400-CNB-000 920772 hydac 3964

HDA 4745-A-5000-AH1-000(psi) 920821 hydac 3964

HDA 4745-A-0009-AH1-000(-1..+9bar) ​​921054 hydac 3964

HDA 4745-A-0600-AN7-000 921682 hydac 3964

HDA 4745-A-0040-AH1-000 921721 hydac 3964

HDA 4745-A-0060-AN1-000 922032 hydac 3964

HDA 4745-A-0100-AN1-000 922033 hydac 3964

HDA 4745-A-0600-AN1-000 922035 hydac 3964

HDA 4745-A-016-000 907278 Hydac 2337

HDA 4745-A-0250-AH1-000 909818 Hydac 2973

HDA 4745-A-0250-AN1-000 909761 Hydac 2973

HDA 4745-A-0250-AN7-000 920330 Hydac 2973

HDA 4745-A-250-031(200bar) 906332 hydac 3361

HDA 4745-A-250-000 906392 hydac 3116

HDA 4745-A-400-000 906393 hydac 3116

HDA 4745-A-016-000 907278 hydac 3116

HDA 4745-A-060-000 907280 hydac 3116

HDA 4745-A-006-000 907304 hydac 3116

HDA 4745-A-600-000 907305 hydac 3116

HDA 4745-B-006-000 907313 hydac 3116

HDA 4745-B-016-000 907314 hydac 3116 The company mainly deals with European and American brands and can source brands from any European country. For example, our key German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengstler, Murr, Schmersal, Samson, EPRO (Emerson Group)

American brands: MOOG, ASCO, MAC, NUMATICS, PARKER, Vickers, Helón (Norgren)

Italian brands: OMAL, ATOS, CAMOZZI, UNIVER, Camozzi

Fast Shipping
Fast shipping for order above $100 by UPS or FedEx
Money Back Guarantee
Within 30 days for an exchange
Flexible Payment
Pay with credit card, PayPal or COD
24/7 Support
Get support at any time