FESTO solenoid valve 577267 in stock
$350.00
VSNC-FC-M52-MD-G14-FN FESTO solenoid valve applicability: 1. Media characteristics: 1) Different types of solenoid valves should be selected for gaseous, liquid, or mixed states; 2) Different specifications of products should be used for different media temperatures, otherwise the coil will burn out, the seals will age, and the lifespan will be severely affected; 3) Media viscosity, usually below 50 cSt. If it exceeds this value, use a multi-functional solenoid valve when the nominal diameter is greater than 15mm; use a high-viscosity solenoid valve when the nominal diameter is less than 15mm.
Brand
FESTO/Germany
Flow Direction
One-way
3C Valve Category
Industrial
Application Areas
Environmental Protection, Biotechnology, Petroleum, Pharmaceutical/Biopharmaceutical, General
FESTO Solenoid Valve 577267 in Stock
FESTO solenoid valves are fundamental automation components used to control fluids. They are actuators, not limited to hydraulic or pneumatic systems. They are used in industrial control systems to adjust the direction, flow rate, speed, and other parameters of the medium. Solenoid valves can be used with different circuits to achieve the desired control, ensuring both precision and flexibility. There are many types of solenoid valves, each playing a different role in the control system. Commonly used types include check valves, safety valves, directional control valves, and speed control valves.
FESTO Solenoid Valve Working Principle
The FESTO solenoid valve contains a sealed chamber with through-holes at different positions, each connecting to a different oil pipe. Inside the chamber is a piston, flanked by two electromagnets. When the coil of one electromagnet is energized, the valve body is attracted to that side. Controlling the movement of the valve body opens or closes different drain holes. The inlet hole is always open, allowing hydraulic oil to enter different drain pipes. The oil pressure then pushes the piston in the cylinder, which in turn moves the piston rod, which in turn drives the mechanical device. Thus, controlling the flow of current to the electromagnets controls the mechanical movement.
Festo - Standard Namur Valve (VDE/VDI 3845) Product List My Favorites Features a NAMUR type connection face with a connection hole, conforming to VDE/VDI 3845 standard. Does not include a solenoid coil or socket.
Order Number Order Code 1 Valve Function Standard Rated Flow Pneumatic Connection Port 1 Drive Type
VSNC-FC-M52-MD-G14-FN; 577267 can replace 183973 MFH-5/2K-FR-NA 5/2
183973 MFH-5/2K-FR-NA 5/2 Single Solenoid 1000 l/min Base Electric
183974 MN1H-5/2K-FR-NA 5/2 Single Solenoid 1000 l/min Base Electric
183977 MFXMH-5/2K-FR-NA 5/2 Single Electric Control 1000 l/min Base Electrical
183978 MGTBH-5/2K-FR-NA 5/2 Single Electric Control 400 l/min Base Electrical
188400 MGTBH-5/2K-FR-110AC-NA 5/2 Single Electric Control 400 l/min Base Electrical
188401 MGTBH-5/2K-FR-230AC-NA 5/2 Single Electric Control 400 l/min Base Electrical
535987 NVF3-MOH-5/2-K-1/4-EX Two-position 5-way or two-position 3-way Single Electric Control 900 l/min G1/4 Electrical
535988 NVF3-MOH-5/2-K-1/4-IA-EX Two-position 5-way or two-position 3-way Single-electric control, 900 l/min, G1/4 electrical type
541645 NVF3-5/2K-1/4-24-EX 5/2 Normally open, single-electric control, 900 l/min, G1/4 electrical type
541646 NVF3-5/2K-1/4-24-NPT-EX 5/2 Normally open, single-electric control, 900 l/min, NPT1/4-18 electrical type
541647 NVF3-5/2K-1/4-120-EX 5/2 Normally open, single-electric control, 900 l/min, G1/4 electrical type
541648 NVF3-5/2K-1/4-120-NPT-EX 5/2 Normally open, single-electric control, 900 l/min, NPT1/4-18 electrical type
547017 VSNB-FC-M52-M-G14-P2 5/2 and 3/2 Single Electric Control 950 l/min G1/4
547019 VSNB-FC-M52-M-G14-1A1-EX4A 5/2 and 3/2 Single Electric Control 950 l/min G1/4 Electrical
547021 VSNB-F-M52-M-G14-P2 5/2 Single Electric Control 950 l/min G1/4
547022 VSNB-F-B52-G14-P2 5/2 Bistable 950 l/min G1/4
547023 VSNB-F-M52-M-G14-1A1-EX4A 5/2 Single Electric Control 950 l/min G1/4 Electrical
547024 VSNB-F-B52-G14-1A1-EX4A 5/2 Dual-Stable 950 l/min G1/4 Electrical
547026 VSNB-FC-M52-MH-G14-1A1 5/2 and 3/2 Single Electrical Control 950 l/min G1/4 Electrical
547028 VSNB-F-M52-MH-G14-1A1 5/2 Single Electrical Control 950 l/min G1/4 Electrical
FESTO Solenoid Valve Selection Criteria:
1. Select the solenoid valve based on pipeline parameters: nominal diameter (DN) and connection method.
1) Determine the nominal diameter (DN) according to the inner diameter of the pipeline or flow requirements on site;
2) Connection method: Generally, for DN>50, a flange connection should be selected; for DN≤50, the connection method can be freely selected according to user needs.
2. Selection of Solenoid Valves Based on Fluid Parameters: Material and Temperature Group
1) Corrosive fluids: Corrosion-resistant solenoid valves and all-stainless steel valves are recommended; Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended;
2) High-temperature fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves are preferred;
Solenoid Valve
Solenoid Valve
3) Fluid state: Fluids can be gaseous, liquid, or mixed, especially for diameters greater than DN25, which must be clearly distinguished;
4) Fluid viscosity: Generally, any viscosity can be selected below 50 cSt. If this value is exceeded, a high-viscosity solenoid valve should be selected.
3. Selecting Solenoid Valves Based on Pressure Parameters: Principle and Structure
1) Nominal Pressure: This parameter has the same meaning as other general-purpose valves, determined by the nominal pressure of the pipeline.
2) Working Pressure: If the working pressure is low, a direct-acting or step-direct-acting principle must be selected. For a minimum working pressure difference of 0.04 MPa, direct-acting, step-direct-acting, and pilot-operated valves can all be selected.
4. Electrical Selection: AC220V and DC24V voltage specifications should be prioritized for convenience.
5. Selecting Based on Continuous Working Time: Normally Closed, Normally Open, or Continuously Energized
1) When the solenoid valve needs to be open for a long time, and the continuous time is longer than the closing time, a normally open type should be selected.
2) If the opening time is short or the opening and closing times are infrequent, a normally closed type should be selected.
3) However, for some safety protection applications, such as furnace and kiln flame monitoring, normally open valves cannot be selected; a continuously energized type should be chosen. 6. Select auxiliary functions according to environmental requirements: explosion-proof, backflow preventer, manual operation, waterproof mist, water spray, and diving protection.
Technical Specifications
Valve Function
Two-position 5-way or two-position 3-way, convertible
Actuation Method
Electrically controlled
Width
32 mm
Standard Nominal Flow Rate
1250 l/min
Working Port
NAMUR Orifice Type
Working Voltage
Through solenoid coil, must be ordered separately
Working Pressure
0.25 MPa ... 0.8 MPa
Working Pressure
2.5 bar ... 8 bar
Structural Features
Piston gate valve
Reset Type
Spring return
Certificate Issuing Mechanism
DNVGL-TAA000011J
Exhaust Function
With throttling option
Sealing Principle
Soft seal
Installation Position
Optional
Compliant Standards
VDI/VDE 3845 (NAMUR)
Manual Control
Lock-lock push-button type
Pilot Type
Pilot-driven
Pilot Air Source
Internal pilot
Flow Direction
Irreversible
Symbol
00991831
Overlap
Positive Overlap
Signal Status Indicator
Installation via Accessory
b Value
0.4
c Value
5.2 l/sbar
Standard Nominal Flow Rate, Exhaust Return 4->3
110 l/min
Close Time
92 ms
Open Time
35 ms
Continuous On-Time
100%
Coil Characteristics
Please refer to the electromagnetic coil; must be ordered separately
Explosion-proof
Information in the certificate must be followed! Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX)
Working Medium
Compressed air, conforming to ISO 8573-1:2010 [7:4:4]
Working and Pilot Medium Description
Can be operated with lubricating media (must be operated with lubricating media continuously thereafter)
Corrosion Resistance Rating CRC
2 - Medium corrosion resistance
Paint Wetting Defect Substance (PWIS) Compliance
VDMA24364-B2-L
Media Temperature
-20 °C ... 60 °C
Ambient Temperature
-20 °C ... 60 °C
Product Weight
415 g
Installation Method
With through-hole
Ventilation Interface
Non-pipe type
Air inlet, port 1
G1/4
Air inlet, port 2
NAMUR port mode
Air inlet, port 3
G1/4
Air inlet, port 4
NAMUR port mode
Air inlet, air port 5
G1/4
Material Specifications
RoHS Compliant
Sealing Material
NBR
Housing Material
Refined Aluminum Alloy
Screw Material
High Alloy Stainless Steel