ATOS valves from Italy
$285.26
DKI-1618-X The Italian ATOS valve consists of an electromagnetic coil and a magnetic core, and is a valve body containing one or more orifices. When the coil is energized or de-energized, the rotation of the magnetic core causes the flow of fluid through the valve body or is cut off, thereby changing the direction of the fluid. The electromagnetic components of the solenoid valve consist of a stationary iron core, a moving iron core, and a coil; the valve body consists of a spool, a spool sleeve, and a spring base. The electromagnetic coil is directly mounted on the valve body, which is enclosed in a sealing tube.
Brand
ATOS/Italian Atos
Flow Direction
Other
3C Valve Category
Industry
Application Areas
Medical & Health, Environmental Protection, Chemical, Petroleum, Mining
Italian ATOS solenoid valves are electromagnetically controlled industrial devices, fundamental components of automation used to control fluids. They are actuators, not limited to hydraulic or pneumatic systems. Used in industrial control systems to adjust the direction, flow rate, speed, and other parameters of the medium. Solenoid valves can be used with different circuits to achieve the desired control, ensuring both precision and flexibility. There are many types of solenoid valves, each playing a different role in the control system. Common types include check valves, safety valves, directional control valves, and speed control valves.
ATOS Valves (Italy)
Working Principle:
ATOS solenoid valves contain a sealed chamber with through-holes at different positions, each connecting to a different oil pipe. Inside the chamber is a piston, flanked by two electromagnets. When the coil of one electromagnet is energized, the valve body is attracted to that side. Controlling the movement of the valve body opens or closes different drain holes. The inlet hole is always open, allowing hydraulic oil to enter different drain pipes. The oil pressure then pushes the piston in the cylinder, which in turn moves the piston rod, which in turn drives the mechanical device. Thus, controlling the flow of current to the electromagnets controls the mechanical movement.
When selecting ATOS solenoid valves, the primary principles should be safety, reliability, applicability, and economy. Secondly, selection should be based on six aspects of the on-site operating conditions (i.e., pipeline parameters, fluid parameters, pressure parameters, electrical parameters, operating method, and special requirements). ATOS (Italy) Valve Selection Criteria:
1. Selecting Solenoid Valves Based on Pipeline Parameters: Nominal Diameter (DN), Connection Type
1) Determine the nominal diameter (DN) based on the pipe's inner diameter or flow requirements.
2) Connection type: Generally, for DN > 50, a flange connection should be selected; for DN ≤ 50, the user can choose freely according to their needs.
2. Selecting Solenoid Valves Based on Fluid Parameters: Material, Temperature Group
1) Corrosive fluids: Corrosion-resistant solenoid valves and all-stainless steel are recommended; Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended.
2) High-Temperature Fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves should be chosen.
3) Fluid State: Fluids can be gaseous, liquid, or mixed, especially for diameters greater than DN 25, which must be clearly distinguished.
4) Fluid Viscosity: Generally, any choice is acceptable below 50 cSt; if it exceeds this value, a high-viscosity solenoid valve should be selected. 3. Selecting Solenoid Valves Based on Pressure Parameters: Principle and Structure
1) Nominal Pressure: This parameter has the same meaning as other general-purpose valves, determined by the nominal pressure of the pipeline.
2) Working Pressure: If the working pressure is low, a direct-acting or step-direct-acting principle must be selected. For a minimum working pressure difference of 0.04 MPa, direct-acting, step-direct-acting, and pilot-operated valves can all be selected.
4. Electrical Selection: AC220V and DC24V voltage specifications should be prioritized for convenience.
5. Selecting Based on Continuous Working Time: Normally Closed, Normally Open, or Continuously Energized
1) When the solenoid valve needs to be open for a long time, and the continuous time is longer than the closing time, a normally open type should be selected.
2) If the opening time is short or the opening and closing times are infrequent, a normally closed type should be selected.
3) However, for some safety protection applications, such as furnace and kiln flame monitoring, normally open valves cannot be selected; a continuously energized type should be chosen. 6. Select auxiliary functions according to environmental requirements: explosion-proof, backflow preventer, manual operation, waterproof mist, water spray, and diving protection.
ATOS Solenoid Valve In-Stock Inventory List:
DKI-1612/A-X 230/50/60AC 24
DKI-1612-X 24DC 24
DKI-1613/A-X 24DC 24
DKI-1613-X 24DC 24
DKI-1618-X 24DC 24
DKI-1630/2/A-X 24DC 24
DKI-1630/2-X 24DC
DKI-1631/2/A-X 24DC 24
DKI-1631/2/WP 24DC
DKI-1631/2/WP-X 230/50/60AC 24
DKI-1631/2-X 230/50/60AC 24
DKI-1631/2-X 24DC
DKI-1632/2/AFI/NC-X 24DC 24
DKI-1632/2/A-X 24DC 24
DKI-1671-X 24DC 24
DKI-1710-X 24DC
DKI-1711/WP-X 24DC 24
DKI-17116-X 24DC
DKI-17119-X 110/50/60AC 24
DKI-17119-X 230/50/60AC
DKI-1711-X 110/50/60AC 24
DKI-1711-X 230/50/60AC The company mainly deals with European and American brands and can source brands from any European country. For example, our key German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengsler, MURR, SCHMERSAL, SAMSON, EPRO (Emerson), MOOG (USA), ASCO (USA), MAC (USA), NUMATICS (USA), PARKER (USA), VICKERS (USA), ROSS (USA), NORGREN (UK), OMAL (Italy), ATOS (Italy), CAMOZZI (Italy), UNIVER (Italy), and KEMOL (Italy).