All products

ATOS solenoid valve DHI-0713-X24DC in stock

$383.31

Italian ATOS DHI-0713-X24DC solenoid valve in stock


Brand

ATOS/Italian Atos

Flow Direction

Other

3C Valve Category

Industry

Application Areas

Medical & Health, Food/Agricultural Products, Chemical, Petroleum, General

ATOS Piston Pumps, ATOS Gear Pumps, ATOS Axial Piston Pumps, ATOS Vane Pumps, ATOS Hydraulic Cylinders, ATOS Relief Valves, ATOS Proportional Valves

ATOS Solenoid Valve Selection Considerations:

ATOS solenoid valve selection should first follow four principles in order: safety, reliability, applicability, and economy. Secondly, it should be based on six aspects of the on-site working conditions (i.e., pipeline parameters, fluid parameters, pressure parameters, electrical parameters, actuation method, and special requirements).

ATOS Solenoid Valve Selection Basis:

1. Selecting the solenoid valve based on pipeline parameters: nominal diameter (DN) and connection method

1) Determine the nominal diameter (DN) according to the on-site pipeline inner diameter or flow requirements;

2) Connection method: Generally, >DN50 requires a flange connection; ≤DN50 can be freely selected according to user needs.

2. Selecting Solenoid Valves Based on Fluid Parameters: Material and Temperature Group

1) Corrosive fluids: Corrosion-resistant solenoid valves and all-stainless steel valves are recommended; Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended.

2) High-temperature fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves are preferred.

3) Fluid state: Fluids can be gaseous, liquid, or mixed, especially when the diameter is greater than DN25, these must be clearly distinguished.

4) Fluid viscosity: Generally, any viscosity can be selected below 50 cSt. If it exceeds this value, a high-viscosity solenoid valve should be selected.

3. Selecting Solenoid Valves Based on Pressure Parameters: Principle and Structural Types

1) Nominal pressure: This parameter has the same meaning as other general-purpose valves and is determined by the nominal pressure of the pipeline.

2) Working pressure: If the working pressure is low, a direct-acting or step-direct-acting principle valve must be selected; when the working pressure difference is above 0.04 MPa, direct-acting, step-direct-acting, and pilot-operated valves can all be selected. 4. Electrical Selection: AC220V or DC24V voltage specifications should be prioritized for convenience.

5. Selection Based on Continuous Operating Time: Normally Closed, Normally Open, or Continuously Energized

1) When the solenoid valve needs to be open for a long time, and the continuous time is longer than the closing time, a normally open type should be selected.

2) If the opening time is short or the opening and closing times are infrequent, a normally closed type should be selected.

3) However, for some safety protection applications, such as furnace and kiln flame monitoring, normally open types cannot be selected; continuously energized types should be chosen.

6. Selection of Auxiliary Functions Based on Environmental Requirements: Explosion-proof, check valve, manual operation, waterproof mist, water spray, submersible.

ATOS Solenoid Valve Selection Principles (Folded Edit Section)

ATOS Solenoid Valve Safety:

1. Corrosive Media: Plastic King Solenoid Valves and All-Stainless Steel Valves are recommended; for highly corrosive media, diaphragm type valves must be selected. 1. For neutral media, solenoid valves with copper alloy valve bodies are preferable; otherwise, rust particles will frequently flake off from the valve body, especially in applications with infrequent operation. Copper cannot be used for ammonia valves.

2. Explosive environments: Appropriate explosion-proof products must be selected. For outdoor installations or dusty environments, waterproof and dustproof models should be chosen.

3. The nominal pressure of the solenoid valve should exceed the maximum working pressure within the pipe.

ATOS Solenoid Valve Applicability:

1. Media Characteristics

1) Different types of solenoid valves should be selected for gaseous, liquid, or mixed states.

2) Different specifications of products should be used for different media temperatures; otherwise, the coil will burn out, the seals will age, and the lifespan will be severely affected.

3) Media viscosity is typically below 50 cSt. If it exceeds this value, a multi-functional solenoid valve should be used for a diameter greater than 15 mm; a high-viscosity solenoid valve should be used for a diameter less than 15 mm.

4) When the cleanliness of the medium is not high, a backwash filter valve should be installed before the solenoid valve. For low pressure, a direct-acting diaphragm solenoid valve can be used.

5) If the medium flows in a directional manner and backflow is not allowed, a bidirectional flow valve is required.

6) The medium temperature should be within the allowable range of the solenoid valve.

2. Piping Parameters

1) Select the valve port and model according to the medium flow direction requirements and pipeline connection method.

2) Select the nominal diameter according to the flow rate and valve Kv value; alternatively, the same as the pipeline inner diameter can be selected.

3) Working pressure difference: For low working pressure differences above 0.04 MPa, an indirect pilot-operated valve can be used; for low working pressure differences close to or less than zero, a direct-acting or step-by-step direct-acting valve must be used. 3. Environmental Conditions

1) The maximum and minimum ambient temperatures should be within acceptable ranges.

2) In environments with high relative humidity or exposure to water droplets or rain, waterproof solenoid valves should be selected.

3) In environments with frequent vibration, bumps, and impacts, special types should be selected, such as marine solenoid valves.

4) In corrosive or explosive environments, corrosion-resistant types should be selected based on safety requirements.

5) If space is limited, multi-functional solenoid valves should be selected, as they eliminate the need for bypasses and three manual valves and facilitate online maintenance.

4. Power Supply Conditions

1) Select AC or DC solenoid valves according to the type of power supply. Generally, AC power is more readily available.

2) For voltage specifications, AC220V and DC24V should be preferred.

3) Power supply voltage fluctuations are typically +10% to -15% for AC and ±10% for DC. If these fluctuations exceed the tolerance, voltage stabilization measures must be taken.

4) The rated current and power consumption should be selected according to the power supply capacity. Note that the VA value is higher during AC startup; indirect-acting solenoid valves should be preferred when capacity is insufficient.

5. Control Accuracy

1) Ordinary solenoid valves only have open and closed positions. Multi-position solenoid valves are required when high control accuracy and stable parameters are needed.

2) Activation Time: The time from the electrical signal being connected or disconnected to the main valve completing its action.

3) Leakage: The leakage values ​​given in the sample are for commonly used economic grades.

ATOS Solenoid Valve Performance Requirements:

1. Reversing Performance

Under specified operating conditions, can the solenoid valve reliably reverse direction after being energized and reliably reset after being de-energized?

2. Pressure Loss

The pressure loss of a solenoid directional valve consists of flow loss and throttling loss caused by fluid flowing through the valve orifice.

3. Internal Leakage

The internal leakage of a solenoid directional valve refers to the leakage from the high-pressure chamber to the low-pressure chamber under specified operating conditions and in various operating positions.

4. Reversing and Reset Time

The time required from the energization of the solenoid to the termination of the valve core's reversing action. Reset time refers to the time required from the de-energization of the solenoid to the valve core returning to its initial position.

5. Reversing Frequency

The maximum number of reversing operations allowed per unit time.

6. Service Life

The service life of the ATOS solenoid valve is defined as the number of reversing operations allowed until major components are damaged, preventing normal reversing and reset actions, or until its main performance indicators significantly deteriorate beyond the specified number of reversing operations. [1]

ATOS Solenoid Valve Stock List:

DHI-0631/2/WP-X 12DC 23

DHI-0631/2/WP-X 220DC 23

DHI-0631/2/WP-X 230/50/60AC

DHI-0631/2P/A-X 24DC

DHI-0631/2P-X 24DC

DHI-0631/2-X 230/50/60AC

DHI-0713-X 110/50/60AC

DHI-0713-X 230/50/60AC

DHI-0713-X 24DC

DHI-0713-X 24DC 23 /PE

DHI-0714/WP-X 230/50/60AC

DHI-0714/WP-X 230/50/60AC 23 /PE

DHI-0714-X 230/50/60AC

DHI-0714-X 24DC

DHI-0715/FI/NC-X 24DC

DHI-0715-X 24DC

DHI-0716-X 24DC

DHI-0717-X 24DC

DHI-0718-X 230/50/60AC

DHI-0718-X 24DC

DHI-0750/2-X 24DC

DHI-0751/2/FI/NC-X 24DC 23

DHI-0751/2/FI/NO-X 24DC 23

DHI-0751/2/WP-X 230/50/60AC DHI-0751/2/WP-X 230/50/60AC 23/PE

DHI-0751/2/WP-X 24DC

DHI-0751/2-X 110/50/60AC 23

DHI-0751/2-X 230/50/60AC

DHI-0751/2-X 24DC

DHO-0630/2/A-X 24DC 20

DHO-0631/2/A-X 24DC 20

DHO-0631/2/L1-X 24DC 20

DHO-0631/2-X 24DC

DHO-0639/O-X 24DC 20

DHO-0710-X 24DC 20

DHO-0711-X 24DC DHO-0713-X 24DC 20

DHO-07191-X 24DC

Our company mainly deals in European and American brands and can source brands from any European country. For example, our key German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengstler, Murr, Schmersal, Samson, EPRO (Emerson subsidiaries)

American brands: MOOG, ASCO, MAC, NUMATICS, PARKER, VICKERS, ROSS

British brands: Norgren

Italian brands: OMAL, ATOS, CAMOZZI, UNIVER, Camozzi

Our business scope includes:

Hydraulic components such as:

Solenoid directional valves, directional valves, check valves, stack valves, relief valves, counterbalancing valves, proportional valves, manual directional valves, flow valves, pressure reducing valves

Throttle valves, pressure control valves, back pressure valves, filling valves, flow dividers, shuttle valves, pressure relays, cartridge valves, pneumatic valves, piston pumps

Gear pumps, vane pumps, cycloidal hydraulic motors, oil coolers, hydraulic cylinders, etc. Pneumatic components include:

Air source processor assemblies, filters, pressure regulating valves, oilers, solenoid valves, pneumatic valves, angle seat valves, manual valves, pull valves, foot valves;

Mechanical valves, check valves, vacuum generators, cylinders, magnetic switches, dampers, pressure gauges, quick couplings, floating couplings;

Pressure gauge switches, water coolers, electric positioners, PU tubing, vacuum suction cups, oil filters, vibrators;

Electrical components include:

Relays, sensors, converters, proximity switches, encoders, programmable controllers;

The company maintains a large inventory, with standard parts readily available. To better serve customers in various industries, the company also distributes other spare parts, with professional sourcing channels and reasonable prices.

The company's products are widely used in industrial machinery, machine tools, plastic machinery, shoe machinery, brick machinery, metallurgy, mining, chemical industry, papermaking, coal mining, shipbuilding, etc.

Fast Shipping
Fast shipping for order above $100 by UPS or FedEx
Money Back Guarantee
Within 30 days for an exchange
Flexible Payment
Pay with credit card, PayPal or COD
24/7 Support
Get support at any time