All products

ATOS proportional directional valve DKZORC-A-151-S5/18 in stock

$296.95

The purpose of Italian ATOS proportional directional valves or servo valves is to achieve flow throttling control through electronic means (of course, pressure control can also be achieved through structural modifications). Since it is throttling control, there will inevitably be energy loss. The difference between servo valves and other valves is that their energy loss is greater because they require a certain flow to maintain the operation of the pre-stage control circuit.


Brand

ATOS/Italian Atos

ATOS Piston Pumps, ATOS Gear Pumps, ATOS Axial Piston Pumps, ATOS Vane Pumps, ATOS Hydraulic Cylinders, ATOS Relief Valves, ATOS Proportional Valves, ATOS Stack Valves

ATOS proportional directional valves control flow in two ways: One is on/off control: either fully open or fully closed, with flow either at maximum or minimum, without intermediate states, such as ordinary solenoid direct-flow valves, solenoid directional valves, and electro-hydraulic directional valves. The other is continuous control: the valve port can open to any degree as needed, thereby controlling the flow rate. These valves can be manually controlled, such as throttle valves, or electrically controlled, such as proportional valves and servo valves. Therefore, the purpose of using proportional valves or servo valves is to achieve flow throttling control electronically (of course, pressure control can also be achieved through structural modifications). Since it is throttling control, there is inevitably energy loss. Servo valves differ from other valves in that their energy loss is greater because they require a certain flow rate to maintain the operation of the pre-stage control circuit.

Differences between ATOS proportional directional valves and servo valves:

ATOS proportional directional valves differ mainly in the following aspects:

1. Different drive devices: Proportional valves are driven by proportional electromagnets; servo valves are driven by force motors or torque motors.

2. Different performance parameters: Hysteresis, dead zone, bandwidth, and filtration accuracy differ, leading to different applications. Servo valves and servo proportional valves are primarily used in closed-loop control systems, while other types of proportional valves are mainly used in open-loop control systems and closed-loop speed control systems.

2.1 Servo valves have no dead zone in the neutral position, while proportional valves do.

2.2 Servo valves have a higher frequency response, reaching up to approximately 200Hz, while proportional valves typically have a maximum frequency of tens of Hz.

2.3 Servo valves have higher requirements for hydraulic fluid, requiring fine filtration to prevent clogging, while proportional valves have lower requirements.

3. Different valve core structures and machining precision: Proportional valves use a valve core + valve body structure, with the valve body also serving as the valve sleeve. Servo valves and servo proportional valves use a valve core + valve sleeve structure.

4. Different neutral position functions. Proportional directional valves have neutral position functions similar to ordinary directional valves, while servo valves only have an O-type neutral position function (E-type for Rexroth products).

5. Different rated pressure drops.

ATOS proportional directional valves have performance between servo valves and proportional valves.

ATOS proportional directional valves are a type of proportional valve used to control flow rate and direction.

ATOS Proportional Directional Valve Extended Information---Automatic control of electrical proportional valves can be divided into intermittent control and continuous control. Intermittent control is on/off control. Pneumatic control systems use on/off directional valves with low operating frequencies to control the opening and closing of the air path. Pressure reducing valves regulate the required pressure, and throttle valves regulate the required flow rate. This traditional pneumatic control system requires multiple pressure reducing valves, throttle valves, and directional valves to achieve multiple output forces and multiple movement speeds. This not only increases the number of components, raising costs and complicating the system structure, but also requires many components to be manually adjusted in advance. Electro-proportional valve control is a type of continuous control, characterized by output that changes proportionally to input, with a certain proportional relationship between the two. Proportional control can be open-loop or closed-loop.

ATOS Proportional Directional Valve Structure and Principle:

When the input signal to the ATOS proportional directional valve increases, the pilot valve 1 of the supply solenoid valve switches, while the exhaust solenoid pilot valve 7 remains in the reset state. The supply pressure then enters the pilot chamber 5 from the SUP port through valve 1. The pressure in the pilot chamber rises, and this pressure acts on the diaphragm 2, opening the supply valve core 4 connected to diaphragm 2 and closing the exhaust valve core 3, generating output pressure. This output pressure is fed back to the control loop 8 via pressure sensor 6. Here, a rapid comparison and correction is performed with the target value until the output pressure is proportional to the input signal, thus demonstrating that the output pressure changes proportionally to the input signal. Because there is no nozzle-baffle mechanism, the valve is insensitive to impurities and has high reliability.

ATOS proportional directional valve features:

1) Enables stepless adjustment of pressure and speed, avoiding the shock phenomenon during directional switching of normally open on/off pneumatic valves.

2) Enables remote and program control.

3) Simplifies the system and greatly reduces the number of components compared to intermittent control.

4) Compared to hydraulic proportional valves, it is smaller, lighter, simpler in structure, and lower in cost, but its response speed is much slower and it is more sensitive to load changes.

5) Low power consumption, low heat generation, and low noise.

6) Does not cause fires and does not pollute the environment. Less affected by temperature changes. ATOS proportional directional valve

DHZO-AE-071-S5/I

DHZO-AE-073-D5/I/10

DHZO-AE-073-S5 10

DHZO-AE-073-S5/I 10

DHZO-AT-073-P3 20

DHZO-ATE-073-P3/B/DP27SB 20

DHZO-T-051-L1

DHZO-T-051-L5 31

DHZO-T-071-D5

DHZO-T-071-L5

DHZO-T-071-S5

DHZO-TE-051-L5/Y 40

DHZO-TE-071-L5

DHZO-TE-071-S5 40/PE DHZO-TE-073-S5

DKZA-A-173-L5/PA-M/7

DKZO-A-151-S5

DKZO-A-171-L5

DKZO-A-173-S5

DKZOR-A-151-S5

DKZOR-A-151-S5/18 40

DKZOR-A-151-S5/B

DKZOR-A-153-L5/B

DKZOR-A-171-D5 40

DKZOR-A-171-L5

DKZOR-A-171-S5

DKZOR-A-171-S5/18

DKZOR-A-173-D5

DKZOR-A-173-L5 DKZOR-A-173-L5/18 40

DKZOR-A-173-L5/Y

DKZOR-A-173-S3

DKZOR-A-173-S5

DKZOR-A-173-S5/18

DKZOR-AE-171-L5 10

DKZOR-AE-171-S5

DKZOR-AE-171-S5 10/WG

DKZOR-AE-171-S5/Y 10

DKZOR-AE-173-D5 10

DKZOR-AE-173-L5 10

DKZORC-A-151-S5/18 The company mainly deals with European and American brands and can source brands from any European country. For example, our key German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengstler, Murr, Schmersal, Samson, EPRO (Emerson Group)

American brands: MOOG, ASCO, MAC, NUMATICS, PARKER, VICKERS, ROSS

British brands: Norgren

Italian brands: OMAL, ATOS, CAMOZZI, UNIVER, Camozzi

Fast Shipping
Fast shipping for order above $100 by UPS or FedEx
Money Back Guarantee
Within 30 days for an exchange
Flexible Payment
Pay with credit card, PayPal or COD
24/7 Support
Get support at any time