WLCA2-55LD - Omron

September 2, 2025

Item Number:WLCA2-55LD

Category: Omron

Price: $48.60 USD / 44.23 EUR

Omron WLCA2-55LD

Details

  • Estimated Lead Time: 4-6 Weeks

  • Manufacturer: Omron

  • WLCA2-55LD

  • Shape/Structure: General-purpose Limit switches

  • Service life: General type

  • Operating mechanism: Snap action

  • Actuator: Roller lever
    17.5 dia. * 7 Sintered stainless steel roller 38 R

  • Frequency: 50/60 Hz

  • Leakage current: Approx. 0.5 mA

  • Switching mechanism: Self-reset mechanism

  • Contact configuration: 2-circuit double break type

  • Contact form: SPST-NO / SPST-NC

  • Load: General load

  • Ratings (AC): Non-Inductive load: Rated voltage: 115 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)

  • Ratings (AC): Inductive load: Rated voltage: 115 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)

  • Ratings (DC): Non-Inductive load: Rated voltage: 12 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO)
    Rated voltage: 24 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 4 A(NC) 3 A(NO)
    Rated voltage: 48 VDC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 2 A(NC) 1.5 A(NO)
    Rated voltage: 115 VDC / Resistive load: 0.8 A(NC) 0.8 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)

  • Ratings (DC): Inductive load: Rated voltage: 12 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO)
    Rated voltage: 24 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 4 A(NC) 4 A(NO)
    Rated voltage: 48 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2 A(NC) 2 A(NO)
    Rated voltage: 115 VDC / Inductive load: 0.8 A(NC) 0.8 A(NO) / Motor load: 0.2 A(NC) 0.2 A(NO)

  • Inrush current: NC: 30 A
    NO: 20 A

  • Indicator: LED (Possible to change between Light when operating and Light when not operating.)
    Voltage: Common use for AC/DC 10 to 115 V
    Leakage current: Approx. 0.5 mA

  • Conduit size: G1/2

  • Earth terminal: Without ground terminal

  • Ambient temperature: Operating: -10 to 80

  • Ambient humidity: Operating: 35 to 95%

  • Shipping Weight: 1.3 Kg