Selection parameters for German GSR solenoid valves
$223.13
Selection parameters for German GSR solenoid valves
Brand
GSR/Germany
Flow Direction
Other
3C Valve Category
Industry
Application Areas
Medical & Health, Environmental Protection, Food/Agricultural Products, Chemical, Petroleum
GSR Solenoid Valve Selection Parameters (Germany):
1. Select the solenoid valve based on pipeline parameters: nominal diameter (DN) and connection type
1) Determine the nominal diameter (DN) according to the inner diameter of the pipeline or flow requirements on site;
2) Connection type: Generally, for DN >50, a flange connection should be selected; for DN ≤50, the connection type can be freely selected according to user needs.
2. Selecting Solenoid Valves Based on Fluid Parameters: Material and Temperature Group
1) Corrosive fluids: Corrosion-resistant solenoid valves and all-stainless steel valves are recommended; Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended.
2) High-temperature fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves are preferred.
3) Fluid state: Fluids can be gaseous, liquid, or mixed, especially when the diameter is greater than DN25, these must be clearly distinguished.
4) Fluid viscosity: Generally, any viscosity can be selected below 50 cSt. If it exceeds this value, a high-viscosity solenoid valve should be selected.
3. Selecting Solenoid Valves Based on Pressure Parameters: Principle and Structural Types
1) Nominal pressure: This parameter has the same meaning as other general-purpose valves and is determined by the nominal pressure of the pipeline.
2) Working pressure: If the working pressure is low, a direct-acting or step-direct-acting principle valve must be selected; for low working pressure differentials above 0.04 MPa, direct-acting, step-direct-acting, and pilot-operated valves can all be selected. 4. Electrical Selection: AC220V or DC24V voltage specifications are preferred for ease of use.
5. Selection Based on Continuous Operating Time: Normally Closed, Normally Open, or Continuously Energized
1) When the solenoid valve needs to be open for a long time, and the duration is longer than the closing time, a normally open type should be selected.
2) If the opening time is short or the opening and closing times are infrequent, a normally closed type should be selected.
3) However, for some safety protection applications, such as furnace and kiln flame monitoring, a continuously energized type cannot be selected.
6. Selection of Auxiliary Functions Based on Environmental Requirements: Explosion-proof, Check Valve, Manual Operation, Water-resistant (fogproof), Water Spray, Submersible
I. Selection of Solenoid Valves Based on Fluid Parameters: Material, Temperature Group
1. Corrosive Fluids: Corrosion-resistant solenoid valves and all-stainless steel are recommended. Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended.
2. High-Temperature Fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves should be chosen.
3. Fluid State: Generally, fluids can be gaseous, liquid, or mixed. This distinction is especially important when ordering valves with a diameter greater than DN25.
4. Fluid Viscosity: Generally, any viscosity can be selected below 50 cSt. If it exceeds this value, a high-viscosity solenoid valve must be selected.
GSR Solenoid Valve - GSR Direct-Acting Solenoid Valve, German GSR solenoid valve parameters are as follows:
II. Selecting a Solenoid Valve Based on Pipeline Parameters: Nominal Diameter (DN) and Connection Type
1. Determine the nominal diameter (DN) based on the inner diameter of the pipeline or the flow rate requirements.
2. Connection type: Generally, for valves >DN50, a flange connection should be selected; for valves ≤DN50, the connection type can be freely selected according to user needs.
GSR 40 Series Pilot-Operated Solenoid Valves (Germany)
Size Range: Thread G1/4~G3
Pressure Range: 0.3~20 bar
Fluid Properties: Neutral, gaseous, or liquid fluids
Fluid Temperature: -10~+130℃
Ambient Temperature: Maximum +35℃
Valve Body Material: Brass, Stainless Steel
Sealing Material: NBR, FKM, EPDM
Standard Voltage: AC: 24/42/110/230V 50/60HZ
DC: 24/110/205V
Protection Class: IP65, DIN40050
gsr D4323.1001.012XX 0-12bar, G1/2
gsr D2208/0401/7008-EE 0-4bar, DN80
gsr A4825/1001/.322-QX 24V
gsr B4327/1001/.322-HA,24V
gsr B0019.000923 OSB-HOLZKISTEN DN50
gsr 022.001013 D2206/0500/7013-DT 0-20bar D
gsr 022.001024 D2206/0501/8005
gsr 022.001020 D2206/0501/7005
gsr G040.001412.090.009.090 230V 50-60HZ
gsr 022.001013 D2206/0500/7013-DT 0-20bar D
gsr B0019.000923 OSB-HOLZKISTEN DN50
gsr B5027/1001/.012 (1-40Bar;DN40;220V;-10℃/+80℃)
gsr D2201/0501/7005
gsr D2201/0501/7008
gsr A52421002.012XX
gsr C01000004/A52421002.012XX
gsr B5027/1001/.012 (1-40Bar;DN40;220V DC;-10℃/+80℃)
gsr A5244/1002/.148-0P
gsr G046.000491.090.002.039 B46210801.702XX
Our company mainly deals in European and American brands and can source brands from any European country. For example, our key German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. We have partnerships with approximately 200 brands, including: German companies such as Henström, MURR, SCHMERSAL, SAMSON, and EPRO (a subsidiary of Emerson); American companies such as MOOG, ASCO, MAC, NUMATICS, PARKER, VICKERS, and ROSS; British companies such as Norgren; Italian companies such as OMAL, ATOS, CAMOZZI, UNIVER, and Camozzi; and companies in the US such as ASCO, VICKERS, MAC, PARKER, MOOG, FAIRCHILD, DENISON, ROSS, UE, MTS, and GEFRAN.