A Rexroth solenoid valve has a sealed chamber with through-holes at different positions, each connecting to a different oil pipe. Inside the chamber is a piston, flanked by two electromagnets. When the coil of one electromagnet is energized, the valve body is attracted to that side. Controlling the movement of the valve body opens or closes different drain holes. The inlet hole is always open, allowing hydraulic oil to enter different drain pipes. The oil pressure then pushes the piston in the cylinder, which in turn moves the piston rod, which in turn drives the mechanical device. Thus, controlling the current to the electromagnets controls the mechanical movement.

Rexroth Solenoid Valve Selection Criteria

The selection of a Rexroth solenoid valve should first follow four principles in order: safety, reliability, applicability, and economy. Secondly, it should be based on six aspects of the on-site operating conditions (i.e., pipeline parameters, fluid parameters, pressure parameters, electrical parameters, operating method, and special requirements). Rexroth Solenoid Valve Selection Criteria:

1. Selection of Solenoid Valve Based on Pipeline Parameters: Nominal Diameter (DN), Connection Type

1) Determine the nominal diameter (DN) based on the inner diameter of the pipeline or flow requirements.

2) Connection type: Generally, for DN > 50, a flange connection should be selected; for DN ≤ 50, the connection type can be freely selected according to user needs.

2. Selection of Solenoid Valve Based on Fluid Parameters: Material, Temperature Group

1) Corrosive fluids: Corrosion-resistant solenoid valves and all-stainless steel are recommended; Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended.

2) High-Temperature Fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves should be chosen.

3) Fluid State: Fluids can be gaseous, liquid, or mixed, especially for diameters greater than DN 25, which must be clearly distinguished.

4) Fluid Viscosity: Generally, any choice is acceptable below 50 cSt; if it exceeds this value, a high-viscosity solenoid valve should be selected. 3. Selecting Solenoid Valves Based on Pressure Parameters: Principle and Structure

1) Nominal Pressure: This parameter has the same meaning as other general-purpose valves, determined by the nominal pressure of the pipeline.

2) Working Pressure: If the working pressure is low, a direct-acting or step-direct-acting principle must be selected. For a minimum working pressure difference of 0.04 MPa, direct-acting, step-direct-acting, and pilot-operated valves can all be selected.

4. Electrical Selection: AC220V and DC24V voltage specifications should be prioritized for convenience.

5. Selecting Based on Continuous Working Time: Normally Closed, Normally Open, or Continuously Energized

1) When the solenoid valve needs to be open for a long time, and the continuous time is longer than the closing time, a normally open type should be selected.

2) If the opening time is short or the opening and closing times are infrequent, a normally closed type should be selected.

3) However, for some safety protection applications, such as furnace and kiln flame monitoring, normally open valves cannot be selected; a continuously energized type should be chosen. 6. Select auxiliary functions according to environmental requirements: explosion-proof, check valve, manual operation, waterproof mist, water spray, and submersible.

Rexroth Solenoid Valve Selection Principles

Safety:

1. Corrosive media: Plastic-coated solenoid valves and all-stainless steel valves are recommended; for highly corrosive media, diaphragm-type valves must be selected. For neutral media, solenoid valves with copper alloy valve bodies are also recommended; otherwise, rust particles will often fall from the valve body, especially in infrequent applications. Copper valves cannot be used for ammonia applications.

2. Explosive environments: Products with the appropriate explosion-proof rating must be selected. For outdoor installations or dusty environments, waterproof and dustproof models should be selected.

3. The nominal pressure of the Rexroth solenoid ball valve should exceed the maximum working pressure in the pipeline.

Rexroth Solenoid Valve Applicability:

1. Media Characteristics

1) Different types of solenoid valves should be selected for gaseous, liquid, or mixed states.

2) Different specifications of products should be used for different media temperatures; otherwise, the coil will burn out, the seals will age, and the lifespan will be severely affected.

3) Media viscosity is generally below 50 cSt. If it exceeds this value, a multi-functional solenoid valve should be used when the nominal diameter is greater than 15 mm; a high-viscosity solenoid valve should be used when the nominal diameter is less than 15 mm.

4) When the media cleanliness is not high, a backflush filter valve should be installed before the solenoid valve. For low pressure, a direct-acting diaphragm solenoid valve can be selected.

5) If the media flows in a directional manner and backflow is not allowed, a bidirectional flow valve is required.

6) The media temperature should be selected within the allowable range of the solenoid valve. 2. Piping Parameters

1) Select the valve port and model according to the medium flow direction requirements and pipeline connection method;

2) Select the nominal diameter according to the flow rate and valve Kv value, or select the same as the pipeline inner diameter;

3) Working pressure difference: For a minimum working pressure difference above 0.04 MPa, an indirect pilot-operated valve can be selected; for a minimum working pressure difference close to or less than zero, a direct-acting or step-by-step direct-acting valve must be selected.

3. Environmental Conditions

1) The maximum and minimum ambient temperatures should be within the allowable range;

2) In environments with high relative humidity or water droplets/rain, a waterproof solenoid valve should be selected;

3) In environments with frequent vibration, bumps, and impacts, a special type should be selected, such as a marine solenoid valve;

4) In corrosive or explosive environments, corrosion-resistant types should be selected based on safety requirements;

5) If space is limited, a multi-functional solenoid valve should be selected, as it eliminates the need for a bypass and three manual valves and facilitates online maintenance. 4. Power Supply Conditions

1) Select AC or DC solenoid valves according to the type of power supply. Generally, AC power is more readily available.

2) Prioritize AC220V or DC24V voltage specifications.

3) Power supply voltage fluctuations are typically +10% to -15% for AC and ±10% for DC. If these fluctuations exceed the tolerance, voltage stabilization measures must be taken.

4) Select the rated current and power consumption according to the power supply capacity. Note that AC has a higher VA value during startup; if the capacity is insufficient, indirect-acting solenoid valves should be preferred.

5. Control Accuracy

1) Ordinary solenoid valves only have two positions: open and closed. For high control accuracy and stable parameters, multi-position solenoid valves should be selected.

2) Activation Time: The time from the electrical signal being connected or disconnected to the main valve completing its action.

3) Leakage: The leakage values ​​given in the sample are for commonly used economic levels.

Rexroth Solenoid Valve Reliability:

1. Service Life: This is not included in the factory testing items but is a type testing item. 1. **Product Quality:** Choose products from reputable manufacturers.

2. **Duty Cycle:** There are three types: continuous duty, intermittent duty, and short-time duty. For applications where the valve is open for extended periods with only short periods of closure, a normally open solenoid valve is recommended.

3. **Operating Frequency:** For applications requiring high operating frequency, a direct-acting solenoid valve is preferred, and AC power is the preferred option.

4. **Actual Reliability:** Strictly speaking, this test is not yet formally included in Chinese solenoid valve standards. To ensure quality, choose products from reputable manufacturers. In some applications, the number of actuations may be low, but high reliability is crucial, such as in fire protection and emergency systems. This should not be taken lightly. For particularly critical applications, double-acting valves with dual backups should be used.

WRPEH6C3B24L-2X/G24K0/A1M 0811404602

4WRPEH6C3B40L-2X/G24K0/A1M 0811404603

4WRPEH6C5B40L-2X/G24K0/A1M 0811404746

4WRPEH6C3B15P-2X/G24K0/A1M 0811404642

4WRPEH6C3B25P-2X/G24K0/A1M 0811404643

4WRPEH6C3B40P-2X/G24K0/A1M 0811404644

4WRPEH6C5B40P-2X/G24K0/A1M 0811404648

4WRPEH6C3B04L-2X/G24K0/F1M 0811404631

4WRPEH6C3B12L-2X/G24K0/F1M 0811404632

4WRPEH6C3B24L-2X/G24K0/F1M 0811404633

4WRPEH6C3B40L-2X/G24K0/F1M 0811404634

4WRPEH6C5B40L-2X/G24K0/F1M 0811404749

4WRPEH6C4B02L-2X/G24K0/A1M 0811404641 4WRPEH6C4B04L-2X/G24K0/A1M 0811404610

4WRPEH6C4B12L-2X/G24K0/A1M 0811404611

4WRPEH6C4B24L-2X/G24K0/A1M 0811404612

4WRPEH6C4B40L-2X/G24K0/A1M 0811404613

4WRPEH6C1B40L-2X/G24K0/A1M 0811404738

4WRPEH6C4B15P-2X/G24K0/A1M 0811404645 4WRPEH6C4B25P-2X/G24K0/A1M 0811404646

4WRPEH6C4B40P-2X/G24K0/A1M 0811404647

4WRPEH6C1B40P-2X/G24K0/A1M 0811404649

4WRPEH6C4B04L-2X/G24K0/F1M 0811404350

4WRPEH6C4B12L-2X/G24K0/F1M 0811404351

4WRPEH6C4B24L-2X/G24K0/F1M 0811404352 4WRPEH6C4B40L-2X/G24K0/F1M 0811404353

4WRPEH6C1B40L-2X/G24K0/F1M 0811404354

4WRPEH6CB04L-2X/G24K0/A1M 0811404741

4WRPEH6CB24L-2X/G24K0/A1M 0811404355 The company mainly deals with European and American brands and can source brands from any European country. For example, our key German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengstler, Murr, Schmersal, Samson, EPRO (Emerson Group)

American brands: MOOG, ASCO, MAC, NUMATICS, PARKER, Vickers, Helón (Norgren)