REXROTH solenoid valve 4WE6FB6X/EG24NZ5L in stock
$438.81
German REXROTH solenoid valve 4WE6FB6X/EG24NZ5L in stock
Brand
REXROTH/Germany Rexroth
Flow Direction
Other
3C Valve Category
Industry
Application Areas
Chemical, Petroleum, Mining, Road/Rail/Marine, Comprehensive
REXROTH solenoid valves are electromagnetically controlled industrial devices, fundamental components of automation used to control fluids. They are actuators, not limited to hydraulic or pneumatic systems. Used in industrial control systems to adjust the direction, flow rate, speed, and other parameters of the medium. Solenoid valves can be used with different circuits to achieve the desired control, ensuring both precision and flexibility. There are many types of solenoid valves, each playing a different role in the control system; commonly used types include check valves, safety valves, directional control valves, and speed regulating valves.
A REXROTH solenoid valve consists of an electromagnetic coil and a magnetic core, and is a valve body containing one or more orifices. When the coil is energized or de-energized, the rotation of the magnetic core causes fluid to flow through the valve body or be cut off, thus changing the fluid direction. The electromagnetic components of a solenoid valve consist of a fixed iron core, a moving iron core, and a coil; the valve body consists of a spool, a spool sleeve, and a spring base. The solenoid coil is directly mounted on the valve body, which is enclosed in a sealing tube, forming a simple and compact assembly. Commonly used solenoid valves in production include 2-position 3-way, 2-position 4-way, and 2-position 5-way valves. Let's first explain the meaning of "2-position": for a solenoid valve, it means energized and de-energized; for the valve it controls, it means open and closed.
Common faults of REXROTH solenoid valves include the valve not operating. Troubleshooting should be done in the following ways:
(1) Loose or detached N-connector of the solenoid valve will not energize it. Tighten the wire.
(2) Burned-out solenoid coil. Disconnect the solenoid valve wiring and measure with a multimeter. If an open circuit is detected, the solenoid coil is burnt out. This can be caused by the coil being subjected to NJ (non-electric shock), resulting in poor insulation and magnetic leakage, leading to excessive current and burnout. Therefore, prevent rainwater from entering the solenoid valve. Additionally, an overly stiff spring, excessive reaction force, or too few coil turns can also cause the coil to burn out due to insufficient suction.
(3) The solenoid valve is stuck. The clearance between the valve sleeve and the valve core of a solenoid valve is very small. When mechanical impurities are introduced or the valve body is rusted, it can easily become stuck. The fundamental solution is to disassemble the solenoid valve, remove the N core and valve core sleeve, and clean them with CCI4 to ensure the valve core moves freely within the valve sleeve. During disassembly, pay attention to the assembly sequence of each component and the external wiring position to ensure correct reassembly and wiring. (5) If it is a pilot-operated solenoid valve, check if the differential pressure in the pipeline is too small. If the differential pressure is too small, the solenoid valve will not work properly. In this case, a direct-acting solenoid valve should be selected. If the differential pressure is too large, far exceeding the design value of the solenoid N, it will also not work properly. In this case, a high-performance solenoid valve should be used.
(5) If dirt in the pipeline blocks the small hole of the pilot valve, the pilot valve cannot open properly, and the main valve cannot open in time. The valve body can be disassembled, the dirt cleaned, and reassembled to ensure normal operation.
(6) In addition, solenoid valves are generally installed horizontally. If they are side-mounted, it may cause the valve to not close tightly, i.e., internal leakage. Side-mounting should be avoided as much as possible. A REXROTH solenoid valve consists of a solenoid coil and a magnetic core, and a valve body containing one or more orifices. When the coil is energized or de-energized, the rotation of the magnetic core causes fluid to flow through the valve body or be cut off, thus changing the direction of fluid flow. The electromagnetic components of a solenoid valve consist of a fixed iron core, a moving iron core, and a coil; the valve body consists of a spool, a spool sleeve, and a spring base. The solenoid coil is directly mounted on the valve body, which is enclosed in a sealing tube, forming a simple and compact assembly. Commonly used solenoid valves in production include 2-position 3-way, 2-position 4-way, and 2-position 5-way valves. Here, let's first explain the meaning of "2-position": for a solenoid valve, it means energized and de-energized; for the valve it controls, it means open and closed.
Rexroth solenoid valves are electromagnetically controlled industrial devices, fundamental components of automation systems used to control fluids. They are actuators, not limited to hydraulic or pneumatic systems. Used in industrial control systems to adjust the direction, flow rate, speed, and other parameters of the medium. Solenoid valves can be used with different circuits to achieve the desired control, ensuring both precision and flexibility. There are many types of solenoid valves, each playing a different role in the control system. Common types include check valves, safety valves, directional control valves, and speed control valves.
4WEH10J4X/6EW220-50NEZ5L
4WEH10J4X/6EG24NEZ5L
4WEH10J4X/6EW220-50NETZ5L
4WEH10J4X/6EG24NETZ5L
4WEH10J4X/6EW220-50NTZ5L
4WEH10J4X/6EG24NTZ5L
4WEH10G4X/6EW220-50NZ5L
4WEH10G4X/6EG24NZ5L
4WEH10G4X/6EW220-50NEZ5L
4WEH10G4X/6EG24NEZ5L
4WEH10G4X/6EW220-50NETZ5L
4WEH10G4X/6EG24NETZ5L
4WEH10G4X/6EW220-50NTZ5L
4WEH10G4X/6EG24NTZ5L
4WEH10H4X/6EW220-50NZ5L
4WEH10H4X/6EG24NZ5L
4WEH10H4X/6EW220-50NEZ5L 4WEH10H4X/6EG24NEZ5L
4WEH10H4X/6EW220-50NETZ5L
4WEH10H4X/6EG24NETZ5L
4WEH10H4X/6EW220-50NTZ5L
4WEH10H4X/6EG24NTZ5L
4WEH10R4X/6EG24NZ5L
4WEH10R4X/6EW220-50NEZ5L
4WEH10R4X/6EG24NEZ5L
4WEH10R4X/6EW220-50NETZ5L
4WEH10R4X/6EG24NETZ5L
4WEH10R4X/6EW220-50NTZ5L 4WEH10R4X/6EG24NTZ5L
4WEH10L4X/6EW220-50NZ5L
4WEH10L4X/6EG24NZ5L
4WEH10L4X/6EW220-50NEZ5L
4WEH10L4X/6EG24NEZ5L The company primarily deals in European and American brands, and can source brands from any European country. For example, key German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, HIRSCHMANN industrial switches, Henschler, MURR, SCHMERSAL, SAMSON, EPRO (a subsidiary of Emerson), and GRAS (Denmark).
American brands include: MOOG, ASCO solenoid valves, MAC solenoid valves, NUMATICS, PARKER pneumatics and hydraulics, VICKERS, and ROSS.
British brands include: Norgren.