- Estimated Lead Time : _7 Working Days \n
- Manufacturer : Mitsubishi Electric \n
- Universal model high speed type QCPU: Q06UDVCPU \n
- control method : Stored program iteration operation \n
- Input / output control method : Refresh method \n(Direct access input / output possible by specifying direct access input / output (DX, DY)) \n
- Programming language :- Sequence control language : Relay symbol word, logic symbolic word, MELSAP 3 (SFC), MELSAP-L, function block, structured text (ST) \n
- Peripheral connection port : USB, Ethernet \n
- Memory card interface : Yes (SD memory card) \n
- processing speed :- Sequence instructions LD X 0 : 1.9 ns \n
- MOV D 0 D 1 : 3.9 ns \n
- Constant scan : 0.5 ~ 2000 ms (Can be set in 0.1 ms increments) \n
- Program capacity : 60K steps (240K bytes) \n
- Memory capacity :- Program memory (drive 0) : 240 KB \n
- Memory card (SD) (Drive 2) : Installed SD memory card (SD / SDHC) capacity (up to 32 GB) \n
- Standard RAM (Drive 3) When the extended SRAM cassette is not used : 768 KB \n
- When using extended SRAM cassette : Capacity when the extended SRAM cassette is not used + capacity of the \nextended SRAM cassette (Extended SRAM cassette can be up to 8 Mbytes) \n
- Standard ROM (Drive 4) : 1025.5 KB \n
- CPU shared memory QCPU standard area : 8 KB \n
- High speed communication area between multiple CPUs : 32 KB \n
- Maximum number of stored files :- Program memory : 124 \n
- Memory card (SD) SD : Root folder: Up to 512 \nsubdirectories: Maximum 65534 \n
- SDHC : Root folder: Maximum 65535 books \nSubdirectory: Up to 65534 books \n
- Standard RAM : 323 books \n
- Standard ROM : 256 \n
- Intelligent functional unit Parameter Maximum setting number :- Initial setting : 4096 pieces \n
- refresh : 2048 pieces \n
- Number of program memory writes : Up to 100,000 times \n
- Number of standard ROM writes : Up to 100,000 times \n
- Number of input / output devices : 8192 points (X / Y 0 to 1 FFF) \n
- Number of input / output points : 4096 points (X / Y 0 to FFF) \n
- Number of device points :- Internal relay [M] : Default 15360 points (M0 to 15359) (changeable) \n
- Latch relay [L] : Default 8192 points (L0 to 8191) (changeable) \n
- Link relay [B] : Default 8192 points (B 0 to 1 FFF) (changeable) \n
- Timer [T] : Default 2048 points (T0 ~ 2047) (shared low-speed timer / high speed timer) (changed) \nthe low-speed timer / high speed timer is specified by the instruction \nunit of measurement of the low-speed timer / high speed timer is set in the parameter \n(low-speed timer: 1 ~ 1000ms , 1 ms \nincrement, default 100 ms)(High-speed timer: 0.01 to 100 ms, 0.01 ms increments, default 10.0 ms) \n
- Integration timer [ST] : Default 0 point (Shared for low speed integration timer / high speed integration timer) (changeable) \nLow speed integration timer / high speed integration timer is set by \ninstruction Set the measurement unit of low speed integration timer / high speed integration timer by parameter \n(low speed integration timer: 1 ~ 1000 ms, 1 ms \nincrement, default 100 ms)(High-speed integration timer: 0.01 to 100 ms, 0.01 ms increments, default 10.0 ms) \n
- Counter [C] : Normal counter: default 1024 points (C 0 ~ 1023) (changeable) \n
- Data register [D] : Default 22528 points (D0 to 22527) (changeable) \n
- Extended data register [D] : Default 0 point (changeable) \n
- Link register [W] : Default 8192 points (W 0 to 1 FFF) (changeable) \n
- Extended link register [W] : Default 0 point (changeable) \n
- Annunciator [F] : Default 2048 points (F0 to 2047) (changeable) \n
- Edge relay [V] : Default 2048 points (V 0 to 2047) (Changeable) \n
- : File register [R] When the extended SRAM cassette is not used : 32768 points (R 0 to 32767) \nUp to 393216 points can be used by block switching \n
- When using Q4 MCA - 1 MBS : 32768 points (R 0 ~ 32767) \nUp to 917504 points can be used by block switching \n
- When using Q4 MCA - 2 MBS : 32768 points (R 0 ~ 32767) \nUp to 144,1792 points can be used by block changeover \n
- When using Q4 MCA - 4 MBS : 32768 points (R 0 to 32767) \nUp to 2490368 points can be used by block switching \n
- When using Q4 MCA - 8 MBS : 32768 points (R 0 to 32767) \nMaximum 4587520 points can be used by block switching \n
- : File register [ZR] When the extended SRAM cassette is not used : 393216 points (ZR 0 to 393215) \nBlockswitchingnot required \n
- When using Q4 MCA - 1 MBS : 917504 points (ZR 0 to 917503) No \nblockswitchingrequired \n
- When using Q4 MCA - 2 MBS : 1441792 points (ZR 0 to 1441791) \nBlockswitchingnot required \n
- When using Q4 MCA - 4 MBS : 2490368 points (ZR 0 to 2490367) \nBlockswitchingnot required \n
- When using Q4 MCA - 8 MBS : 4587520 points (ZR 0 to 4587519) \nBlockswitchingnot required \n
- Link special relay [SB] : Default 2048 points (SB 0 to 7 FF) (changeable) \n
- Link special register [SW] : Default 2048 points (SW 0 to 7 FF) (changeable) \n
- Step relay [S] : Default 8192 points (S0 to 8191) (changeable) \n
- Index register / general operation register [Z] : Up to 20 points (Z 0 ~ 19) \n
- Index register [Z] (when 32-bit qualification of ZR device is specified) : Up to 10 points (Z0 to 18) (Use index register [Z] as double word) \n
- Pointer [P] : 4096 points (P 0 ~ 4095) (Device number is fixed) Usable \nrange of local pointer / common pointer can be set by parameter \n
- Interrupt pointer [I] : 256 points (I 0 to 255) (the number of device points is fixed) \nPeriodic interval of system interrupt pointer I 28 to 31 can be set by parameter (0.5 to 1000.0 ms, 0.5 ms increments) \nDefault I 28: 100 ms, I 29: 40 ms, I 30: 20 ms , I31: 10 ms \n
- Special relay [SM] : 2048 points (SM 0 to 2047) (the number of device points is fixed) \n
- Special register [SD] : 2048 points (SD 0 to 2047) (the number of device points is fixed) \n
- Function input [FX] : 16 points (FX 0 to F) (the number of device points is fixed) \n
- Function output [FY] : 16 points (FY 0 to F) (the number of device points is fixed) \n
- Function register [FD] : 5 points (FD 0 ~ 4) (Device number is fixed) \n
- Link direct device : Device that directly accesses link device \nCC-Link IE, MELSECNET / H Specific only Specifications \n: J ?? X ??, J ?? Y ??, J ?? Y ??, J ?? W ??, J ?? B ??, J ?? SW ??, J ?? SB ?? \n
- Intelligent functional unit device : Device \nspecificationthat directly accesses buffer memory of intelligent function moduleFormat: U ?? G ?? \n
- Latch (power outage hold) range : L 0 to 8191 (default 8192 points) \n[latch range can be set for B, F, V, T, ST, C, D, W] \n
- RUN / PAUSE contact : One point of each RUN / PAUSE contact can be set from X 0 to 1 FFF \n
- Clock function : Year, month, day, hour, minute, second, day of the week (Automatic leap year discrimination) \naccuracy: -2.97 ~ + 3.75s (. TYP + 0.39s) / d at 0 ? \naccuracy: -2.97 ~ + 3.75s (TYP + .0.39 s) / d at 25 _ C \nAccuracy: -12.77 to + 2.13 s (TYP. -5.32 s) / d at 55 _ C \n
- Allowable momentary power failure time : Depends on power supply unit \n
- DC 5 V Internal current consumption : 0.58 A (single CPU unit) / 0.6 A (when extended SRAM cassette is installed) \n
- External dimensions :- Height (H) : 98 mm \n
- Width (W) : 27.4 mm \n
- Depth (D) : 115 mm \n
- mass : 0.20 kg \n
- Built-in Ethernet function section : \n
- Transmission specification :- Data transmission speed : 100/10 Mbps \n
- Communication mode : Full duplex / half duplex \n
- Transmission method : Baseband \n
- Hub and node longest distance : 100 m \n
- Maximum number of nodes / connection 10 BASE-T : Up to 4 cascade connections \n
- 100 BASE-TX : Maximum 2 cascade connections \n
- Number of connections : Socket communication, MELSOFT connection, MC protocol total 16 pieces \n1 for FTP \n
- CC-Link IE Field Network Basic Performance Specification : \n
- 1 Number of network connections :- Master station : One \n
- Slave station : 16 units \n
- Number of occupied stations of slave stations : 1 to 4 stations \n
- Maximum number of links per network :- RX : 1024 points \n
- RY : 1024 points \n
- RWr : 512 points \n
- RWw : 512 points \n
- Maximum number of links per station :- : Master station RX : 1024 points \n
- RY : 1024 points \n
- RWr : 512 points \n
- RWw : 512 points \n
- : Slave station RX : 64 points (occupies 1 station) \n128 points (occupies 2 stations) \n192 points (occupies 3 stations) \n256 points (occupies 4 stations) \n
- RY : 64 points (occupies 1 station) \n128 points (occupies 2 stations) \n192 points (occupies 3 stations) \n256 points (occupies 4 stations) \n
- RWr : 32 points (occupies 1 station) \n64 points (occupies 2 stations) \n96 points (occupies 3 stations) \n128 points (occupies 4 stations) \n
- RWw : 32 points (occupies 1 station) \n64 points (occupies 2 stations) \n96 points (occupies 3 stations) \n128 points (occupies 4 stations) \n
- UDP port number used for cyclic transmission : 61450 \n
- Transmission specification :- Data transmission speed : 100 Mbps \n
- Number of cascade connection stages 100 BASE-TX : Check the manufacturer of the switching hub to be used for the number of connectable stages when using the switching hub. \n
- Transmission path format : Star type \n
- communication cable : Ethernet cable that meets 100BASE-TX standard \n
- Maximum inter-station distance : Up to 100 m (conforming to ANSI / TIA / EIA - 568 - B (Category 5 e)) \n
- Total extension distance : Depends on system configuration \n
- Shipping Weight : 2 Kg \n