Distributor of Industrial Automation Parts

One Stop Sourcing and Supply

Fast delivery, reliable combined shipping

20 years of experience
Leading industry innovation

Flexible Payment
Pay in 20+ local currencies

Ship worldwide via DHL, FedEx, UPS & more

FX3U-ENET-ADP - Mitsubishi

August 26, 2025

Item Number:FX3U-ENET-ADP

Category: Mitsubishi

Price: $212.94 USD / 193.78 EUR

Mitsubishi Electric FX3U-ENET-ADP

Details

  • Estimated Lead Time: 5-7 Working Days
  • Manufacturer: Mitsubishi Electric
  • Ethernet interface block FX3U-ENET-ADP
  • Transmission Specifications Data transmission speed: 100Mbps or 10Mbps,
  • Communication mode: Full / half duplex
  • Transmission method: Baseband
  • The maximum segment length: 100m
  • The maximum number of nodes / connection: 10BASE-T: cascade up to four stages_
    100BASE-TX: cascade up to two-stage_
    above is the connection possible number of stages at the time of use repeater hub._
    Can be connected to the number of stages at the time of switching hub used, please check with the manufacturer of the switching hub to be used.
  • Connector: RJ45
  • function: 鐠 MELSOFT connection_
    communicate by 鐠 MC protocol_
    direct connection with 鐠 MELSOFT (simple connection)_
    and connection CPU search function__nd time setting function_
    ? time setting function (SNTP client), executable only after the establishment of the trigger conditions_
    diagnosis from 鐠 MELSOFT function_
    data monitoring function
  • Number of connections: MELSOFT connection + MC protocol + data monitoring ? 4 connection
  • It can be connected to the number of the basic unit: One_
    Ethernet adapter, as well as the communication function expansion board and other communication special adapter, and 1 channel the communication channel (CH) occupation.
  • Apply PLC: FX3S, FX3G (V2.00 or later), FX3U (since V3.10), FX3GC (V2.00 or later), FX3UC (V3.10 or later)_
    connection to the FX3S is required FX3S-CNV-ADP._
    Connection to the FX3G is required FX3G-CNV-ADP._
    FX3U, connection to the FX3UC-32MT-LT (-2), you must have the function expansion board.
  • mass: 0.1kg
  • Power Specifications: _
  • Power supply: 30mA / DC5V (internal power supply from DC5V power of the basic unit)
  • Allowable momentary power failure time: As well as the sequencer to be connected
  • Ambient temperature: 0 ~ 55 __ 鐠虹熅鐠虹熅鐠 operation, -25 ~ 75 __ 鐠虹熅鐠虹熅鐠 during storage
  • Relative humidity: 5 ~ 95% RH (non-condensing) ...... operation
  • Vibration resistance When the DIN rail mounting Frequency: 10 ~ 57Hz: Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes)
  • Frequency: 57 ~ 150Hz: Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes)
  • Direct mounting at the time Frequency: 10 ~ 57Hz: Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes)
  • Frequency: 57 ~ 150Hz: Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes)
  • Impact resistance: 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each
  • Anti-noise: Noise voltage 1,000Vp-p, noise width 1濞揰, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator
  • Withstand voltage: All terminals and between the ground terminal: AC500V 1 minute
  • Insulation resistance: All terminals and between the ground terminal: DC500V 5M_ more in insulation resistance tester
  • Working environment: Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly
  • Use advanced: 2000m or less_
    can not be used in the pressurized environment to more than atmospheric pressure.__here is a possibility of failure.
  • Shipping Weight : 1 Kg