- Estimated Lead Time : In stock. Usually ships in 7-10 working days.
- Manufacturer : Mitsubishi Electric
- FX3U-2HC
- High speed counter block FX 3 U - 2 HC
- Number of input channels : 2 ch
- Input format : Open collector, differential line driver (Differential line driver output type encoder is connected to 5 V terminal)
- Input voltage : DC 5 V, DC 12 V, DC 24 V can be selected by connection terminal
- Maximum response frequency 1 phase 1 input : 200 kHz or less
- 1 phase 2 input : 200 kHz or less
- 2 phase input : 200 kHz or less (1 multiplication), 100 kHz or less (2 multiplication), 50 kHz or less (4 multiplication)
- Count range : When 32 bits are specified: -2, 147, 483, 648 to +2, 147, 483, 647 When 16 bits are specified: 0 to 65,535 (upper limit value can be specified by BFM # 3, # 2, # 43,
- Count mode : Automatic up / down (However, the count direction is determined by the following command of 1 phase 1 input counter.) [H / W up / down] Up / down counting is performed by OFF / ON of A phase input terminal. [S / W up / down] Up / down is performed with the current value (K0 / K1) of BFM # 1, # 41.
- Matching output (comparison) : When the current value of the counter matches the comparison setting value, the comparison output is set (ON) within 30 濞揰 and cleared (OFF) within 100 濞揰 by the reset command.
- Output format : Open collector output 2 points 5 VDC to 24 V 0.5 A
- Display (LED) : _ A, _ B, DIS, PRE, YH 1, YH 2, POWER, UP, DOWN
- Number of occupied I / O points : 8 points (either input or output may be considered)
- Application sequencer :For connection to FX5U, FX5UC, FX5 - CNV - BUS or FX5 - CNV - BUSC is connected to FX5U, FX5U, FX3U (V2.20 or higher), FX3UC Is required. Depending on the system configuration, please choose either.To connect to FX3UC, FX2NC - CNV - IF or FX3UC - 1PS - 5V is required.
- mass : 0.2 Kg
- Power supply : DC 5 V 245 mA (internal power supply from the sequencer)
- Ambient temperature : 0 to 55 _ C. ... Operating -25 to 75 _ C. ..... Save
- Relative humidity : 5 to 95% RH (noncondensing).... in operation
- Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)
- Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
- Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)
- Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)
- Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse
- Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 濞揰, rising 1 ns, with noise si
- tor with period of 30 to 100 Hz
- Withstand voltage : Between all terminals and ground terminal: 500 VAC for 1 minute
- Insulation resistance : Between all terminals and ground terminal: 500 MV DC 500 M_ or more with an insulation resistance meter
- ground : Class D grounding (grounding resistance: 100 _ or less)Grounding should be dedicated ground or common ground.
- Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
- Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
- Shipping Weight : 1.2 Kg
Distributor of Industrial Automation Parts
One Stop Sourcing and Supply
Fast delivery, reliable combined shipping
20 years of experience
Leading industry innovation
Flexible Payment
Pay in 20+ local currencies
Ship worldwide via DHL, FedEx, UPS & more

September 1, 2025
Item Number:FX3U-2HC
Category: Mitsubishi
Price: $312.48 USD / €284.36 EUR
High speed counter block FX 3 U - 2 HC
Details
Related Items
September 23, 2025
293Transistor Block: PM100RRS060

September 23, 2025
273Universal model QCPU Q10UDEHCPU

September 23, 2025
293Redundant PLC CPU Module: Q12PRHCPU

September 23, 2025
299Universal model QCPU Q13UDHCPU