- Estimated Lead Time : In stock. Usually ships in 7-10 working days.
- Manufacturer : Mitsubishi Electric
- FX2N-48ER
- I / O expansion unit FX2N-48ER
- Application sequencer : FX1N, FX3G, FX2N, FX3U
- mass : 0.85 Kg
- Rated voltage : AC 100 V to 240 V
- Voltage tolerance range : AC 85V ~ 264V
- Rated frequency : 50/60 Hz
- Power supply fuse : 250 V 5 A
- Inrush current : AC 100 V: maximum 40 A 5 ms or less AC 200 V: maximum 60 A 5 ms or less
- power consumption : 35W
- 24 VDC service power supply : 24 VDC 460 mA or less When connecting input / output extension block, 24 VDC service power is consumed.
- Input specification :
- Number of input points : 24 points
- Input connection shape : Removable terminal block (M3 screw)
- Input format : sink
- Input signal voltage : DC 24 V _ 10%
- Input impedance : 4.3 k_
- Input signal current : 5 mA / 24 VDC
- Input ON sensitivity current : 3.5 mA or more
- Input OFF sensitivity current : 1.5 mA or less
- Input response time : About 10 ms
- Input signal format : No-voltage contact input or NPN open collector transistor
- Input circuit insulation : Photocoupler insulation
- Input operation display : LED on the panel when input is ON
- Number of output points : 24 points
- Output connection shape : Removable terminal block (M3 screw)
- Output type / format : relay
- External power supply : AC 250 V DC 30 V or less
- Maximum load Resistive load : Please set the total load current per 2A / 1 point common as follows. . Output 4 points / common: 8 A or less . Output 8 points / common: 8 A or less
- Inductive load : 80VA
- Minimum load : DC 5 V 2 mA (reference value)
- Response time OFF ??ON : About 10 ms
- ON ??OFF : About 10 ms
- Circuit insulation : Mechanical insulation
- Output operation indication : When the relay coil is energized LED on the panel is lit
- Ambient temperature : 0 to 55 _ C. ... Operating -25 to 75 _ C. ..... Save
- Relative humidity : 5 to 95% RH (noncondensing).... in operation
- Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
- Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (80 minutes in total in total) The criterion is based on IEC 61131-2
- Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
- Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2
- Impact resistance : 147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2
- Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 濞揰, rising 1 ns, with noise si
- tor with period of 30 to 100 Hz
- Withstand voltage : Between the power supply terminal (AC power supply) and the earth terminal: AC 1500 V for 1 minute 24 VDC Service power supply and between the input terminal (24 VDC) and the earth terminal: 500 V AC for 1 minute Between the output terminal (relay)
- Insulation resistance : Between each terminal and earth terminal: 500 MV DC 500 M_ or more with an insulation resistance meter
- ground : Class D grounding (grounding resistance: 100 _ or less)Grounding should be dedicated ground or common ground.
- Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
- Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
- Shipping Weight : 1.9 Kg
Distributor of Industrial Automation Parts
One Stop Sourcing and Supply
Fast delivery, reliable combined shipping
20 years of experience
Leading industry innovation
Flexible Payment
Pay in 20+ local currencies
Ship worldwide via DHL, FedEx, UPS & more

September 1, 2025
Item Number:FX2N-48ER
Category: Mitsubishi
Price: $257.04 USD / €233.91 EUR
I / O expansion unit FX2N-48ER
Details
Related Items
September 23, 2025
293Transistor Block: PM100RRS060

September 23, 2025
273Universal model QCPU Q10UDEHCPU

September 23, 2025
293Redundant PLC CPU Module: Q12PRHCPU

September 23, 2025
299Universal model QCPU Q13UDHCPU