All products

ATOS solenoid valve DLOH-2C-UX in stock

$230.35

Safety considerations for Italian ATOS solenoid valves: 1. Corrosive media: Plastic-coated solenoid valves and all-stainless steel valves are recommended; for highly corrosive media, diaphragm-type valves must be selected. For neutral media, solenoid valves with copper alloy valve bodies are also recommended; otherwise, rust particles will often flake off from the valve body, especially in applications with infrequent operation. Copper valves cannot be used for ammonia.


Brand

ATOS/Italian Atos

Flow Direction

Other

3C Valve Category

Industry

Application Areas

Chemical, Petroleum, Energy, Electrical, General

ATOS Piston Pumps, ATOS Gear Pumps, ATOS Axial Piston Pumps, ATOS Vane Pumps, ATOS Hydraulic Cylinders, ATOS Relief Valves, ATOS Proportional Valves, ATOS Stack Valves

ATOS solenoid valves are electromagnetically controlled industrial devices, fundamental components for fluid control in automation systems. They are actuators, not limited to hydraulic or pneumatic systems. Used in industrial control systems to adjust the direction, flow rate, speed, and other parameters of the medium. Solenoid valves can be used with different circuits to achieve the desired control, ensuring both precision and flexibility. There are many types of solenoid valves, each playing a different role in the control system. The most common are check valves, safety valves, directional control valves, and speed control valves.

ATOS Solenoid Valve Working Principle

An ATOS solenoid valve contains a sealed chamber with through-holes at different locations, each connecting to a different oil pipe. Inside the chamber is a piston, flanked by two electromagnets. When the coil of one electromagnet is energized, the valve body is attracted to that side. Controlling the movement of the valve body opens or closes different drain holes. The inlet hole is always open, allowing hydraulic oil to enter different drain pipes. The oil pressure then pushes the piston in the cylinder, which in turn moves the piston rod, which in turn drives the mechanical device. Thus, controlling the flow of current to the electromagnets controls the mechanical movement.

ATOS Solenoid Valve Selection Criteria

The selection of an ATOS solenoid valve should first follow four principles in order of priority: safety, reliability, applicability, and economy. Secondly, it should be based on six aspects of the on-site operating conditions (i.e., pipeline parameters, fluid parameters, pressure parameters, electrical parameters, operating method, and special requirements). ATOS Solenoid Valve Selection Criteria:

1. Selection of Solenoid Valves Based on Pipeline Parameters: Nominal Diameter (DN), Connection Type

1) Determine the nominal diameter (DN) based on the inner diameter of the pipeline or flow requirements.

2) Connection type: Generally, for DN >50, a flange connection should be selected; for DN ≤50, the connection type can be freely selected according to user needs.

2. Selection of Solenoid Valves Based on Fluid Parameters: Material, Temperature Group

1) Corrosive fluids: Corrosion-resistant solenoid valves and all-stainless steel are recommended; Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended.

2) High-Temperature Fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves should be chosen.

3) Fluid State: Fluids can be gaseous, liquid, or mixed, especially when the diameter is greater than DN25, it is essential to distinguish between these states.

4) Fluid Viscosity: Generally, any fluid can be selected below 50 cSt; if it exceeds this value, a high-viscosity solenoid valve should be selected. 3. Selecting Solenoid Valves Based on Pressure Parameters: Principle and Structure

1) Nominal Pressure: This parameter has the same meaning as other general-purpose valves, determined by the nominal pressure of the pipeline.

2) Working Pressure: If the working pressure is low, a direct-acting or step-direct-acting principle must be selected. For a minimum working pressure difference of 0.04 MPa, direct-acting, step-direct-acting, and pilot-operated valves can all be selected.

4. Electrical Selection: AC220V and DC24V voltage specifications should be prioritized for convenience.

5. Selecting Based on Continuous Working Time: Normally Closed, Normally Open, or Continuously Energized

1) When the solenoid valve needs to be open for a long time, and the continuous time is longer than the closing time, a normally open type should be selected.

2) If the opening time is short or the opening and closing times are infrequent, a normally closed type should be selected.

3) However, for some safety protection applications, such as furnace and kiln flame monitoring, normally open valves cannot be selected; a continuously energized type should be chosen. 6. Select auxiliary functions according to environmental requirements: explosion-proof, check valve, manual operation, waterproof mist, water spray, and submersible.

Selection

ATOS Solenoid Valve

Principles:

Safety:

1. Corrosive media: Plastic-coated solenoid valves and all-stainless steel valves are recommended; for highly corrosive media, diaphragm type valves must be selected. For neutral media, solenoid valves with copper alloy valve bodies are also recommended; otherwise, rust particles will often fall from the valve body, especially in infrequent applications. Copper materials cannot be used for ammonia valves.

2. Explosive environments: Products with the corresponding explosion-proof rating must be selected. For outdoor installations or dusty environments, waterproof and dustproof models should be selected.

3. The nominal pressure of the solenoid valve should exceed the highest working pressure in the pipeline.

ATOS Solenoid Valve Selection Basis

ATOS Solenoid Valve

Selection should first follow the four principles of safety, reliability, applicability, and economy, and then be based on six aspects of on-site conditions (i.e., pipeline parameters, fluid parameters, pressure parameters, electrical parameters, operating mode, and special requirements). ATOS Solenoid Valves

Selection Criteria:

1. Selecting the solenoid valve based on pipeline parameters: Nominal diameter (DN), connection type

1) Determine the nominal diameter (DN) based on the inner diameter of the pipeline or flow requirements on site;

2) Connection type: Generally, for DN >50, a flange connection should be selected; for DN ≤50, the connection type can be freely selected according to user needs.

2. Selecting the solenoid valve based on fluid parameters: Material, temperature group

1) Corrosive fluids: Corrosion-resistant solenoid valves and all-stainless steel are recommended; Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended;

2) High-temperature fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves should be chosen;

3) Fluid state: Generally, gaseous, liquid, or mixed states are possible, especially for diameters greater than DN25, which must be clearly distinguished;

4) Fluid viscosity: Generally, any choice is possible below 50 cSt; if it exceeds this value, a high-viscosity solenoid valve should be selected. 3. Selecting Solenoid Valves Based on Pressure Parameters: Principle and Structure

1) Nominal Pressure: This parameter has the same meaning as other general-purpose valves, determined by the nominal pressure of the pipeline.

2) Working Pressure: If the working pressure is low, a direct-acting or step-direct-acting principle must be selected. For a minimum working pressure difference of 0.04 MPa, direct-acting, step-direct-acting, and pilot-operated valves can all be selected.

4. Electrical Selection: AC220V and DC24V voltage specifications should be prioritized for convenience.

5. Selecting Based on Continuous Working Time: Normally Closed, Normally Open, or Continuously Energized

1) When the solenoid valve needs to be open for a long time, and the continuous time is longer than the closing time, a normally open type should be selected.

2) If the opening time is short or the opening and closing times are infrequent, a normally closed type should be selected.

3) However, for some safety protection applications, such as furnace and kiln flame monitoring, normally open valves cannot be selected; a continuously energized type should be chosen. 6. Select auxiliary functions according to environmental requirements: explosion-proof, backflow preventer, manual operation, waterproof mist, water spray, and diving protection.

ATOS Solenoid Valve Stock List:

DHI-0611-X 24DC 23

DHI-0612/A-X 24DC

DHI-0613/A-X 24DC 23

DHI-0613/WP-X 230AC

DHI-0613-X 230/50/60AC

DHI-0613-X 24DC

DHI-0614-X 24DC

DHI-0616/A-X 230/50/60AC

DHI-0618/A-X 24DC 23

DHI-0630/2/A-X 230/50/60AC 23

DHI-0630/2/A-X 24DC 23

DHI-0630/2-X 24DC

DHI-0631/1/2/A-X 24DC

DHI-0631/2/A-IX 24DC

DHI-0631/2/A-X 110/50/60AC 23

DHI-0631/2/A-X 230/50/60AC 23

DHI-0631/2/P-X 24DC

DHI-0631/2/WP-X 12DC 23

DHI-0631/2/WP-X 220DC 23

DHI-0631/2/WP-X 230/50/60AC

DHI-0631/2P/A-X 24DC

DHI-0631/2P-X 24DC

DHI-0631/2-X 230/50/60AC DHI-0713-X 110/50/60AC

DHI-0713-X 230/50/60AC

DHI-0713-X 24DC

DHI-0713-X 24DC 23/PE

DHI-0714/WP-X 230/50/60AC

DHI-0714/WP-X 230/50/60AC 23 /PE

DHI-0714-X 230/50/60AC

DHI-0714-X 24DC

DHI-0715/FI/NC-X 24DC

DHI-0715-X 24DC

DHI-0716-X 24DC

DHI-0717-X 24DC

DHI-0718-X 230/50/60AC DHI-0718-X 24DC

DHI-0750/2-X 24DC

Our company mainly deals in European and American brands and can source brands from any European country. For example, our key German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengstler, Murr, Schmersal, Samson, EPRO (Emerson Group)

American brands: MOOG, ASCO, MAC, NUMATICS, PARKER, Vickers, Helón (Norgren)

Italian brands: OMAL, ATOS, CAMOZZI, UNIVER, Camozzi

Fast Shipping
Fast shipping for order above $100 by UPS or FedEx
Money Back Guarantee
Within 30 days for an exchange
Flexible Payment
Pay with credit card, PayPal or COD
24/7 Support
Get support at any time