All products

ATOS solenoid valve DKI-1713/WP-X 230AC in stock

$401.16

For ATOS solenoid valves, other issues include: internal leakage → check for damaged seals and improper spring assembly; external leakage → loose connections or damaged seals → tighten screws or replace seals; noise when the ATOS solenoid valve is energized → loose fasteners on the head, tighten them; voltage fluctuations outside the allowable range, adjust the voltage; impurities or unevenness on the iron core contact surface, clean or replace it promptly.


Brand

ATOS/Italian Atos

Flow Direction

Unidirectional

3C Valve Category

Industry

Application Areas

Chemical, Agriculture, Forestry, Animal Husbandry and Fishery, Petroleum, Mining, Comprehensive

ATOS Solenoid Valve Daily Operation Troubleshooting

ATOS solenoid valve selection should first follow four principles in order: safety, reliability, applicability, and economy. Secondly, it should be selected based on six aspects of the on-site working conditions (i.e., pipeline parameters, fluid parameters, pressure parameters, electrical parameters, actuation method, and special requirements).

ATOS Solenoid Valve Selection Basis:

1. Selecting the solenoid valve based on pipeline parameters: nominal diameter (DN) and connection method

1) Determine the nominal diameter (DN) according to the on-site pipeline inner diameter or flow requirement;

2) Connection method: Generally, >DN50 requires a flange connection; ≤DN50 can be freely selected according to user needs.

2. Selection of Solenoid Valves Based on Fluid Parameters: Material and Temperature Group

1) Corrosive fluids: Corrosion-resistant solenoid valves and all-stainless steel valves are recommended; Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended;

2) High-temperature fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves are preferred;

3) Fluid state: Fluids can be gaseous, liquid, or mixed, especially for diameters greater than DN25, which must be clearly distinguished;

4) Fluid viscosity: Generally, any viscosity can be selected below 50 cSt. If the viscosity exceeds this value, a high-viscosity solenoid valve should be selected. DHU-0631/2-X 24DC

DHU-0632/2/A-X 24DC 20

DHU-0632/2-X 24DC 20

DHU-0639/C-X 24DC 20

DHU-0671-X 24DC

DHU-0710/L1-X 24DC 20

DHU-0710-X 24DC

DHU-0711/WP-X 24DC 20

DHU-07119-X 24DC 20

DHU-0711-X 24DC

DHU-0713/1-X 24DC

DHU-0713/WP-X 24DC 20

DHU-0713P-X 24DC 20

DHU-0713-X 24DC DHU-07149-X 24DC 20

DHU-0714-X 24DC

DHU-0718-X 24DC

DHU-0750/2/FI/NC-X 24DC 20

DHU-0750/2-X 24DC

DHU-0751/2-00 20 /WG

DHU-0751/2P-X 24DC 20

DHU-0751/2-X 24DC

DHU-6751/2P-X 24DC

DKI-1610/A-X 24DC 24

DKI-1610-X 24DC

DKI-1611-X 24DC

DKI-1612/A-X 230/50/60AC 24

DKI-1612-X 24DC 24 DKI-1613/A-X 24DC 24

DKI-1613-X 24DC 24

DKI-1618-X 24DC 24

DKI-1630/2/A-X 24DC 24

DKI-1630/2-X 24DC

DKI-1631/2/A-X 24DC 24

DKI-1631/2/WP 24DC

DKI-1631/2/WP-X 230/50/60AC 24

DKI-1631/2-X 230/50/60AC 24

DKI-1631/2-X 24DC

DKI-1632/2/AFI/NC-X 24DC 24

DKI-1632/2/A-X 24DC 24 DKI-1671-X 24DC 24

DKI-1710-X 24DC

DKI-1711/WP-X 24DC 24

ATOS solenoid valves are electromagnetically controlled industrial devices, fundamental components of automation systems used to control fluids. They are actuators, not limited to hydraulic or pneumatic systems. Used in industrial control systems to adjust the direction, flow rate, speed, and other parameters of the medium. Solenoid valves can be used with different circuits to achieve the desired control, ensuring both precision and flexibility. There are many types of solenoid valves, each playing a different role in the control system. Commonly used types include check valves, safety valves, directional control valves, and speed control valves.

I. ATOS Solenoid Valve Fails After Power-On

Check power wiring for faulty connections → Rewire and reconnect connectors

Check power voltage within ± operating range → Adjust to normal range

Coil detached → Resolder

Coil short-circuited → Replace coil

Opposite operating pressure differential → Adjust pressure differential → or replace with a suitable solenoid valve

Overheating fluid → Replace with a suitable solenoid valve

Impurities causing jamming of the solenoid valve's main valve core and moving iron core → Clean; replace seals if damaged and install a filter

Excessive liquid viscosity, excessive frequency, or expired lifespan → Replace product

II. ATOS Solenoid Valve Fails to Close

Main valve core or moving iron core seal damaged → Replace seals

Excessive fluid temperature or viscosity → Replace with a suitable solenoid valve

Impurities entering the solenoid valve core or moving iron core → Clean

Expired or deformed spring → Replace

Clogged throttling orifice/balance hole → Clean promptly

Excessive operating frequency or expired lifespan → Select or replace product

III. Other Situations Internal leakage → Check for damaged seals and improper spring assembly.

External leakage → Loose connections or damaged seals → Tighten screws or replace seals.

Noise during power-on → Loose fasteners on the head; tighten them. Voltage fluctuations outside the allowable range; adjust the voltage. Impurities or unevenness on the core's contact surface; clean or replace promptly.

Fast Shipping
Fast shipping for order above $100 by UPS or FedEx
Money Back Guarantee
Within 30 days for an exchange
Flexible Payment
Pay with credit card, PayPal or COD
24/7 Support
Get support at any time