All products

ATOS solenoid valve DHI-0713-X24DC23/PE in stock

$465.33

The Italian ATOS solenoid valve consists of an electromagnetic coil and a magnetic core, and is a valve body containing one or more orifices. When the coil is energized or de-energized, the rotation of the magnetic core causes fluid to flow through the valve body or be cut off, thereby changing the direction of fluid flow. The electromagnetic components of the solenoid valve consist of a fixed iron core, a moving iron core, and a coil; the valve body consists of a spool, a spool sleeve, and a spring base. The electromagnetic coil is directly mounted on the valve body, which is enclosed in a sealing tube, forming a simple and compact assembly.


Brand

ATOS/Italian Atos

Flow Direction

Other

3C Valve Category

Industry

Application Areas

Chemical, Petroleum, Mining, Road/Rail/Marine, Comprehensive

ATOS Gear Pumps, ATOS Axial Piston Pumps, ATOS Vane Pumps, ATOS Hydraulic Cylinders

ATOS solenoid valves have a sealed chamber with through-holes at different positions, each connecting to a different oil pipe. In the center of the chamber is a piston, and on either side are two electromagnets. When the coil of one electromagnet is energized, the valve body is attracted to that side. By controlling the movement of the valve body, different drain holes are opened or closed. The inlet hole is always open, allowing hydraulic oil to enter different drain pipes. The oil pressure then pushes the piston in the cylinder, which in turn drives the piston rod, which in turn drives the mechanical device. This way, controlling the on/off state of the electromagnet controls the mechanical movement.

ATOS Solenoid Valve Selection Criteria:

1. Selecting the solenoid valve based on pipeline parameters: Nominal diameter (DN), connection type

1) Determine the nominal diameter (DN) based on the inner diameter of the pipeline or flow requirements.

2) Connection type: Generally, for DN > 50, a flange connection should be selected; for DN ≤ 50, the user can choose freely according to their needs.

2. Selecting the solenoid valve based on fluid parameters: Material, temperature group

1) Corrosive fluids: Corrosion-resistant solenoid valves and all-stainless steel are recommended; Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended.

2) High-temperature fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves should be chosen.

3) Fluid state: Valves can be gaseous, liquid, or mixed, especially for diameters greater than DN 25, which must be clearly distinguished.

4) Fluid viscosity: Generally, any choice is acceptable below 50 cSt; if it exceeds this value, a high-viscosity solenoid valve should be selected. 3. Selecting Solenoid Valves Based on Pressure Parameters: Principle and Structure

1) Nominal Pressure: This parameter has the same meaning as other general-purpose valves, determined by the nominal pressure of the pipeline.

2) Working Pressure: If the working pressure is low, a direct-acting or step-direct-acting principle must be selected. For low working pressure differentials above 0.04 MPa, direct-acting, step-direct-acting, and pilot-operated valves can all be selected.

4. Electrical Selection: AC220V and DC24V voltage specifications should be prioritized for convenience.

5. Selecting Based on Continuous Working Time: Normally Closed, Normally Open, or Continuously Energized

1) When the solenoid valve needs to be open for a long time, and the continuous time is longer than the closing time, a normally open type should be selected.

2) If the opening time is short or the opening and closing times are infrequent, a normally closed type should be selected.

3) However, for some safety protection applications, such as furnace and kiln flame monitoring, normally open valves cannot be selected; a continuously energized type should be chosen. 6. Select auxiliary functions according to environmental requirements: explosion-proof, check valve, manual operation, waterproof mist, water spray, submersible.

ATOS Solenoid Valves

ATOS Solenoid Valve Selection Criteria:

1. Select the solenoid valve based on pipeline parameters: nominal diameter (DN) and connection type.

1) Determine the nominal diameter (DN) according to the inner diameter of the pipeline or flow requirements on site;

2) For connection type, generally, flange connections should be selected for DN >50, while for DN ≤50, the connection type can be freely selected according to user needs.

2. Selection of Solenoid Valves Based on Fluid Parameters: Material and Temperature Group

1) Corrosive fluids: Corrosion-resistant solenoid valves and all-stainless steel valves are recommended; Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended;

2) High-temperature fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves are preferred;

3) Fluid state: Fluids can be gaseous, liquid, or mixed, especially for diameters greater than DN25, which must be clearly distinguished;

4) Fluid viscosity: Generally, any viscosity can be selected below 50 cSt. If the viscosity exceeds this value, a high-viscosity solenoid valve should be selected. ATOS Solenoid Valve Stock List:

DHI-0631/2-X 230/50/60AC

DHI-0713-X 110/50/60AC

DHI-0713-X 230/50/60AC

DHI-0713-X 24DC

DHI-0713-X 24DC 23 /PE

DHI-0714/WP-X 230/50/60AC

DHI-0714/WP-X 230/50/60AC 23 /PE

DHI-0714-X 230/50/60AC

DHI-0714-X 24DC

DHI-0715/FI/NC-X 24DC

DHI-0715-X 24DC

DHI-0716-X 24DC

DHI-0717-X 24DC

DHI-0718-X 230/50/60AC

DHI-0718-X 24DC

DHI-0750/2-X 24DC

DHI-0751/2/FI/NC-X 24DC 23

DHI-0751/2/FI/NO-X 24DC 23

DHI-0751/2/WP-X 230/50/60AC

DHI-0751/2/WP-X 230/50/60AC 23/PE

DHI-0751/2/WP-X 24DC

DHI-0751/2-X 110/50/60AC 23

DHI-0751/2-X 230/50/60AC

DHI-0751/2-X 24DC

DHO-0630/2/A-X 24DC 20

DHO-0631/2/A-X 24DC 20

DHO-0631/2/L1-X 24DC 20

DHO-0631/2-X 24DC

DHO-0639/O-X 24DC 20

DHO-0710-X 24DC 20

DHO-0711-X 24DC The company mainly deals with European and American brands and can source brands from any European country. For example, our key German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengstler, Murr, Schmersal, Samson, EPRO (Emerson Group)

American brands: MOOG, ASCO, MAC, NUMATICS, PARKER, VICKERS, ROSS

British brands: Norgren

Italian brands: OMAL, ATOS, CAMOZZI, UNIVER, Camozzi

Fast Shipping
Fast shipping for order above $100 by UPS or FedEx
Money Back Guarantee
Within 30 days for an exchange
Flexible Payment
Pay with credit card, PayPal or COD
24/7 Support
Get support at any time