ATOS solenoid valve DHA-0631/2/GK/WP/24DC25/BT
$357.21
Italian ATOS solenoid valve DHA-0631/2/GK/WP/24DC25/BT
Brand
ATOS/Italian Atos
Flow Direction
Other
3C Valve Category
Industry
Application Areas
Chemical, Petroleum, Energy, Electrical, Comprehensive
ATOS Proportional Valves, ATOS Stack Valves, ATOS Solenoid Valves, ATOS Amplifiers, ATOS Solenoid Directional Valves, ATOS Pressure Reducing Valves
ATOS solenoid valve selection should first follow four principles in order: safety, reliability, applicability, and economy. Secondly, it should be based on six aspects of the on-site working conditions (i.e., pipeline parameters, fluid parameters, pressure parameters, electrical parameters, actuation method, and special requirements).
ATOS Solenoid Valve Selection Basis:
1. Selecting the solenoid valve based on pipeline parameters: nominal diameter (DN) and connection method
1) Determine the nominal diameter (DN) according to the on-site pipeline inner diameter or flow requirements;
2) Connection method: Generally, >DN50 requires a flange connection; ≤DN50 can be freely selected according to user needs.
2. Selecting Solenoid Valves Based on Fluid Parameters: Material and Temperature Group
1) Corrosive fluids: Corrosion-resistant solenoid valves and all-stainless steel valves are recommended; Ultra-clean edible fluids: Food-grade stainless steel solenoid valves are recommended.
2) High-temperature fluids: Solenoid valves made with high-temperature resistant electrical and sealing materials should be selected, and piston-type valves are preferred.
3) Fluid state: Fluids can be gaseous, liquid, or mixed, especially when the diameter is greater than DN25, these must be clearly distinguished.
4) Fluid viscosity: Generally, any viscosity can be selected below 50 cSt. If it exceeds this value, a high-viscosity solenoid valve should be selected.
3. Selecting Solenoid Valves Based on Pressure Parameters: Principle and Structural Types
1) Nominal pressure: This parameter has the same meaning as other general-purpose valves and is determined by the nominal pressure of the pipeline.
2) Working pressure: If the working pressure is low, a direct-acting or step-direct-acting principle valve must be selected; when the minimum working pressure difference is above 0.04 MPa, direct-acting, step-direct-acting, and pilot-operated valves can all be selected. 4. Electrical Selection: AC220V or DC24V voltage specifications are preferred for ease of use.
5. Selection Based on Continuous Operating Time: Normally Closed, Normally Open, or Continuously Energized
1) When the solenoid valve needs to be open for a long time, and the duration is longer than the closing time, a normally open type should be selected.
2) If the opening time is short or the opening and closing times are infrequent, a normally closed type should be selected.
3) However, for some safety protection applications, such as furnace and kiln flame monitoring, a normally open type cannot be selected; a continuously energized type should be chosen.
6. Selection of Auxiliary Functions Based on Environmental Requirements: Explosion-proof, Check Valve, Manual Operation, Water-resistant (fogproof), Water Spray, Submersible.
ATOS solenoid valves are electromagnetically controlled industrial devices, fundamental components of automation used to control fluids. They are actuators, not limited to hydraulic or pneumatic systems. They are used in industrial control systems to adjust the direction, flow rate, speed, and other parameters of the medium. Solenoid valves can be used with different circuits to achieve the desired control, ensuring both accuracy and flexibility. There are many types of solenoid valves, each playing a different role in a control system. Commonly used types include check valves, safety valves, directional control valves, and speed control valves.
The principle of an ATOS solenoid valve: It combines direct-acting and pilot-operated principles. When there is no pressure difference between the inlet and outlet, energizing the valve causes the electromagnetic force to lift the pilot valve and the main valve's closing element sequentially, opening the valve. When the inlet and outlet reach the starting pressure difference, energizing the valve causes the electromagnetic force to actuate the pilot valve, increasing the pressure in the lower chamber of the main valve and decreasing the pressure in the upper chamber, thus using the pressure difference to push the main valve open. When de-energized, the pilot valve uses spring force or medium pressure to push the closing element downwards, closing the valve.
ATOS Solenoid Valve Stock List:
DHI-0611-X 24DC 23
DHI-0612/A-X 24DC
DHI-0613/A-X 24DC 23
DHI-0613/WP-X 230AC
DHI-0613-X 230/50/60AC
DHI-0613-X 24DC
DHI-0614-X 24DC
DHI-0616/A-X 230/50/60AC
DHI-0618/A-X 24DC 23
DHI-0630/2/A-X 230/50/60AC 23
DHI-0630/2/A-X 24DC 23
DHI-0630/2-X 24DC
DHI-0631/1/2/A-X 24DC
DHI-0631/2/A-IX 24DC
DHI-0631/2/A-X 110/50/60AC 23
DHI-0631/2/A-X 230/50/60AC 23
DHI-0631/2/P-X 24DC
DHI-0631/2/WP-X 12DC 23
DHI-0631/2/WP-X 220DC 23
DHI-0631/2/WP-X 230/50/60AC
DHI-0631/2P/A-X 24DC
DHI-0631/2P-X 24DC
DHI-0631/2-X 230/50/60AC DHI-0713-X 110/50/60AC
DHI-0713-X 230/50/60AC
DHI-0713-X 24DC
DHI-0713-X 24DC 23 /PE
ATOS Explosion-proof Solenoid Valve DHA-0630/2/GK/WP 24DC 25/BT
ATOS Explosion-proof Solenoid Valve DHA-0610/GICWP 24DC 25/BT
ATOS Explosion-proof Solenoid Valve DHA-0713/NPT 24DC
ATOS Explosion-proof Solenoid Valve DHA-0713/GKAVP 24DC 25/BT
ATOS Explosion-proof Solenoid Valve DHA-0711/GK/WP 24DC 25/BT
ATOS Explosion-proof Solenoid Valve DHA-0631/2/GK/WP 24DC BT
ATOS Explosion-proof Solenoid Valve DHA-0613/GKWP 24DC 25
ATOS Italy 12
Hydraulic Pumps
Fixed Displacement Pumps: Vane Pumps, Radial Piston Pumps, Gear Pumps. Variable Pumps: Vane Pumps, Axial Piston Pumps, Proportional Control Pumps – Multi-unit Pumps – Manual Pumps – Atex Explosion-proof Pumps
Hydraulic Cylinders: Servo Cylinders, Hydraulic Cylinders, Standard Cylinders, Explosion-proof Cylinders, Stainless Steel Cylinders
Conventional Valves & Stack Valves: Relief Valves, Pilot-operated Valves, Two-stage Solenoid Valves, Safety Valves, Directional Opening/Closing Controls, Pneumatic Directional Valves, Hydraulic Directional Valves, Explosion-proof Valves
Our company mainly deals with European and American brands and can source brands from any European country. For example, our advantageous German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengstler, Murr, Schmersal, Samson, EPRO (Emerson Group)
American brands: MOOG, ASCO, MAC, NUMATICS, PARKER, VICKERS, ROSS
British brands: Norgren
Italian brands: OMAL, ATOS, CAMOZZI, UNIVER, Camozzi

