ATOS proportional valve DHRZA-P5-012/25/GK/WP in stock
$320.88
The Italian ATOS proportional valve system uses low-frequency on-off directional valves to control the airflow. Pressure reducing valves regulate the required pressure, and throttle valves regulate the required flow rate. This traditional pneumatic control system requires multiple pressure reducing valves, throttle valves, and directional valves to achieve multiple output forces and speeds. This not only increases the number of components, raising costs and complicating the system, but also necessitates manual pre-adjustment of many components.
Brand
ATOS/Italian Atos
ATOS Proportional Valve Structure and Principle:
When the input signal to the ATOS proportional valve increases, the pilot valve 1 of the supply solenoid valve switches, while the exhaust solenoid pilot valve 7 remains in the reset state. The supply pressure then enters the pilot chamber 5 from the SUP port through valve 1. The pilot chamber pressure rises, and the air pressure acts on the diaphragm 2, causing the supply valve core 4 connected to diaphragm 2 to open, and the exhaust valve core 3 to close, generating output pressure. This output pressure is fed back to the control circuit 8 via pressure sensor 6. Here, a rapid comparison and correction is performed with the target value until the output pressure is proportional to the input signal, thus demonstrating that the output pressure changes proportionally to the change in the input signal. Because there is no nozzle-baffle mechanism, the valve is insensitive to impurities and has high reliability.
Differences between ATOS Proportional Valves and Servo Valves
The main differences are as follows:
1. Different drive devices. The proportional valve's drive device is a proportional electromagnet; the servo valve's drive device is a force motor or torque motor;
2. Different performance parameters. 2.1 Servo valves have no dead zone in the neutral position, while proportional valves do. Therefore, their applications differ. Servo valves and servo proportional valves are mainly used in closed-loop control systems, while other proportional valve structures are mainly used in open-loop control systems and closed-loop speed control systems.
2.2 Servo valves have a higher frequency response (response frequency), reaching up to around 200Hz, while proportional valves generally have a maximum frequency of tens of Hz.
2.3 Servo valves have higher requirements for hydraulic fluid, requiring fine filtration to prevent clogging, while proportional valves have lower requirements.
3. Valve core structure and machining precision differ. Proportional valves use a valve core + valve body structure, with the valve body also serving as the valve sleeve. Servo valves and servo proportional valves use a valve core + valve sleeve structure.
4. Neutral position functions differ. Proportional directional valves have neutral position functions similar to ordinary directional valves, while servo valves only have an O-type neutral position function (E-type for Rexroth products).
5. Rated pressure drop differs.
ATOS proportional valves control flow in two ways: On-off control and Continuous control. On-off control means the valve is either fully open or fully closed, with the flow rate either at its maximum or minimum, without intermediate states. Examples include ordinary solenoid direct-flow valves, solenoid directional valves, and electro-hydraulic directional valves. Continuous control allows the valve to open to any desired degree, thus controlling the flow rate. These valves can be manually controlled, such as throttle valves, or electrically controlled, such as proportional valves and servo valves. Therefore, the purpose of using proportional or servo valves is to achieve throttling control of flow rate electrically (and, with structural modifications, pressure control, etc., can also be achieved). Since it's throttling control, there is inevitably energy loss. Servo valves differ from other valves in that their energy loss is greater because they require a certain flow rate to maintain the operation of the upstream control circuit.
DHZO-AE-073-S5/I 10
DHZO-AT-073-P3 20
DHZO-ATE-073-P3/B/DP27SB 20
DHZO-T-051-L1
DHZO-T-051-L5 31
DHZO-T-071-D5
DHZO-T-071-L5
DHZO-T-071-S5
DHZO-TE-051-L5/Y 40
DHZO-TE-071-L5
DHZO-TE-071-S5 40/PE
DHZO-TE-073-S5
DKZA-A-173-L5/PA-M/7
DKZO-A-151-S5 DKZO-A-171-L5
DKZO-A-173-S5
DKZOR-A-151-S5
DKZOR-A-151-S5/18 40
DKZOR-A-151-S5/B
DKZOR-A-153-L5/B
DKZOR-A-171-D5 40
DKZOR-A-171-L5
DKZOR-A-171-S5
DKZOR-A-171-S5/18
DKZOR-A-173-D5
DKZOR-A-173-L5
DKZOR-A-173-L5/18 40
DKZOR-A-173-L5/Y
DKZOR-A-173-S3 DKZOR-A-173-S5
DKZOR-A-173-S5/18
DKZOR-AE-171-L5 10
DKZOR-AE-171-S5
DKZOR-AE-171-S5 10/WG
DKZOR-AE-171-S5/Y 10
DKZOR-AE-173-D5 10
DKZOR-AE-173-L5 10
DKZORC-A-151-S5/18
DKZOR-T-151-L5
DKZOR-T-151-L5/Y
DKZOR-T-153-L5
DKZOR-T-171-D5
DKZOR-T-171-L5
DKZOR-T-171-S5 DKZOR-T-171-S5/Y
DKZOR-T-173-L5 40
DKZOR-TE-170-L5 40
DKZOR-TE-171-L5
DKZOR-TE-171-L5/I 40
Our company mainly deals in European and American brands and can purchase brands from any European country. For example, our advantageous German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengstler, Murr, Schmersal, Samson, EPRO (Emerson Group)
American brands: MOOG, ASCO, MAC, NUMATICS, PARKER, VICKERS, ROSS
British brands: Norgren
Italian brands: OMAL, ATOS, CAMOZZI, UNIVER, Camozzi