ATOS proportional valve AQFR-20 in stock
$333.21
The main differences between Italian ATOS proportional valves and servo valves are as follows: 1. Different drive devices. The drive device for proportional valves is a proportional electromagnet; the drive device for servo valves is a force motor or torque motor; 2. Different performance parameters. Characteristics such as hysteresis, dead zone, bandwidth, and filtration accuracy differ, thus their applications differ. Servo valves and servo proportional valves are mainly used in closed-loop control systems, while other types of proportional valves are mainly used in open-loop control systems and closed-loop speed control systems; 2.1 Servo valves have no dead zone in the neutral position, while proportional valves do; 2.2 The frequency response (frequency response) of servo valves differs.
Brand
ATOS/Italian Atos
Differences between ATOS Proportional Valves and Servo Valves
The main differences are as follows:
1. Different drive devices. The drive device for proportional valves is a proportional electromagnet; the drive device for servo valves is a force motor or torque motor.
2. Different performance parameters. Characteristics such as hysteresis, dead zone, bandwidth, and filtration accuracy differ, leading to different applications. Servo valves and servo-proportional valves are mainly used in closed-loop control systems, while other types of proportional valves are mainly used in open-loop control systems and closed-loop speed control systems.
2.1 Servo valves have no dead zone in the neutral position, while proportional valves do.
2.2 Servo valves have a higher frequency response, reaching up to around 200Hz, while proportional valves generally have a maximum frequency of tens of Hz.
2.3 Servo valves have higher requirements for hydraulic fluid, requiring fine filtration to prevent clogging, while proportional valves have lower requirements.
3. Different valve core structures and machining precision. Proportional valves use a valve core + valve body structure, with the valve body also serving as a valve sleeve. Servo valves and servo proportional valves use a valve core + valve sleeve structure.
4. Different neutral position functions. Proportional directional valves have neutral position functions similar to ordinary directional valves, while servo valves only have an O-type neutral position function (E-type for Rexroth products).
5. Different rated pressure drops.
ATOS proportional valves have performance between servo valves and proportional valves.
Proportional directional valves are a type of proportional valve used to control flow rate and direction.
Extended Information---Automatic control of electric proportional valves can be divided into intermittent control and continuous control. Intermittent control is on/off control. Pneumatic control systems use on/off directional valves with low operating frequencies to control the opening and closing of the air path. Pressure reducing valves regulate the required pressure, and throttle valves regulate the required flow rate. This traditional pneumatic control system requires multiple pressure reducing valves, throttle valves, and directional valves to achieve multiple output forces and multiple movement speeds. This not only increases the number of components, raising costs and complicating the system structure, but also requires many components to be manually adjusted in advance. Electro-proportional valve control is a type of continuous control, characterized by an output that changes proportionally to the input, with a certain proportional relationship between the two. Proportional control can be open-loop or closed-loop.
ATOS Proportional Valve Structure and Principle
When the input signal increases, the pilot valve 1 of the supply solenoid valve switches, while the exhaust solenoid pilot valve 7 is in the reset state. The supply pressure then enters the pilot chamber 5 from the SUP port through valve 1. The pressure in the pilot chamber rises, and this pressure acts on the diaphragm 2, opening the supply valve core 4 connected to diaphragm 2 and closing the exhaust valve core 3, generating output pressure. This output pressure is fed back to the control loop 8 via pressure sensor 6. Here, a rapid comparison and correction is performed with the target value until the output pressure is proportional to the input signal, thus demonstrating that the output pressure changes proportionally to the input signal. Because there is no nozzle-baffle mechanism, the valve is insensitive to impurities and has high reliability.
ATOS proportional valves control flow in two ways: On-off control and Continuous control. On-off control means the valve is either fully open or fully closed, with the flow rate either at its maximum or minimum, without intermediate states. Examples include ordinary solenoid direct-flow valves, solenoid directional valves, and electro-hydraulic directional valves. Continuous control allows the valve to open to any desired degree, thus controlling the flow rate. These valves can be manually controlled, such as throttle valves, or electrically controlled, such as proportional valves and servo valves. Therefore, the purpose of using proportional or servo valves is to achieve throttling control of flow rate electrically (and, with structural modifications, pressure control, etc., can also be achieved). Since it's throttling control, there is inevitably energy loss. Servo valves differ from other valves in that their energy loss is greater because they require a certain flow rate to maintain the operation of the upstream control circuit.
ATOS proportional valve
DHZO-T-071-L5
DHZO-T-071-S5
DHZO-TE-051-L5/Y 40
DHZO-TE-071-L5
DHZO-TE-071-S5 40/PE
DHZO-TE-073-S5
DKZA-A-173-L5/PA-M/7
DKZO-A-151-S5
DKZO-A-171-L5
DKZO-A-173-S5
DKZOR-A-151-S5
DKZOR-A-151-S5/18 40
DKZOR-A-151-S5/B
DKZOR-A-153-L5/B
DKZOR-A-171-D5 40 DKZOR-A-171-L5
DKZOR-A-171-S5
DKZOR-A-171-S5/18
DKZOR-A-173-D5
DKZOR-A-173-L5
DKZOR-A-173-L5/18 40
DKZOR-A-173-L5/Y
DKZOR-A-173-S3
DKZOR-A-173-S5
DKZOR-A-173-S5/18
DKZOR-AE-171-L5 10
DKZOR-AE-171-S5
DKZOR-AE-171-S5 10/WG
DKZOR-AE-171-S5/Y 10
DKZOR-AE-173-D5 10 DKZOR-AE-173-L5 10
DKZORC-A-151-S5/18
DKZOR-T-151-L5
DKZOR-T-151-L5/Y
Our company mainly deals in European and American brands and can source brands from any European country. For example, our advantageous German brands include: BURKERT, DEMAG, HAWE, REXROTH, HYDAC, PILZ relays, FESTO, IFM sensors, E+H, HEIDENHAIN, P+F sensors, SICK, TURCK, and HIRSCHMANN industrial switches. German brands: Hengstler, Murr, Schmersal, Samson, EPRO (Emerson Group)
American brands: MOOG, ASCO, MAC, NUMATICS, PARKER, VICKERS, ROSS
British brands: Norgren
Italian brands: OMAL, ATOS, CAMOZZI, UNIVER, Camozzi

